8.3 Breaker bar removal , inversion and replacement
•
Unscrew the retaining screws and remove the upper hopper
•
Remove the side hopper by unscrewing the 3 nuts ( fig. 13 ) .
•
Remove the transmission belt casing as shown in fig. 15 .
•
Remove the galvanised hole plate .
•
Manuallty turn the rotor to align the cutter shaft with the
aperture.
•
Insert the seeger pliers and remove the ring as shown in fig. 16
( chaff cutter side ) .
•
Remove the shaft , taking care to note the position of the
spacers separating the breaker bars ( fig. 17 ) .
•
If necessary replace the breaker bars . Take care to replace the
previously removed spacers in the same position on the cutter
shaft .
Caution !
Partial replacement of the breaker bars must be carried
out respecting the opposite position for balancing .