![Captron Electronic safeCAP SC30 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/captron-electronic/safecap-sc30/safecap-sc30_operating-instructions-manual_2554873022.webp)
Safety figures
Value
Unit
Lifetime
20
years
Test Time Interval
1
months
TIP
Refer to the safety relay instructions for more technical specifications.
10.6 Technical specifications, safety relay PNOZ
s6
General data
Value
Wire cross-section
0.2 - 2.5 mm
2
Operating temperature
- 10 to + 55°C
Storage temperature
- 40 to + 85°C
Switching capacity
max. 6 A / 240 V AC (AC1)
max. 5 A / 230 V AC (AC15)
max. 6 A / 24 V DC (DC1)
max. 5 A / 24 V AC (DC13)
External contact fuse
Fast-acting safety fuse
Slow-blow safety fuse
Circuit breaker
10 A
6 A
6 A, 24V AC/DC, characteristic B/C
Safety figures
Value
Unit
Category
4
PL
e
MTTF
d
100
a, years
DC
avg
99.0
[%]
PFH
d
2,62e-09
[1/h]
average usage d
op
220
[days/year]
average usage h
op
12
[hours/day]
22/25
1.1
safeCAP SC30
Original operating instructions