![Captron Electronic safeCAP SC30 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/captron-electronic/safecap-sc30/safecap-sc30_operating-instructions-manual_2554873021.webp)
Safety figures
Value
Unit
Test Time Interval
2
[years]
TIP
Refer to the safety relay instructions for more technical specifications.
10.5 Technical specifications, safety relay
MCR-225
General data
Wire cross-section
0.2 - 2.5 mm
2
Operating temperature
- 25 to + 55°C
Storage temperature
- 25 to + 85 °C
Switching capacity
NO 3 A / 230 V AC (AC 15)
NC 1 A / 230 V AC (AC15)
NO 1 A / 24 V DC (DC 13)
NC 1 A / 24 V DC (DC 13)
Resistance to short circuit
Max. safety fuse
Circuit breaker
6 A gL
C 8 A
Safety figures
Value
Unit
Category
4
PL
e
MTTF
d
90
a, years
DC
avg
99.0
[%]
PFH
d
7,51e-09
[1/h]
average usage d
op
220
[days/year]
average usage h
op
12
[hours/day]
t
cycle
95
[s/cycle]
safeCAP SC30
Original operating
instructions
1.1