•  Push the 

RINSE

button. 

INSERT FILTER / PRESS 

   

STEAM

.

•  Remove water tank, remove old filter. Keep the 

   extension rod. Rinse new filter under running water, 
   attach to extension and install in water tank. Fill with 
   fresh water and insert water tank into machine.

•  Place a 20 oz. container under the Steam Nozzle and 

   push either steam button. The display shows 

FILTER 

   

RINSING

. Initially, the water may have a slight 

   discoloration. After 60 seconds the water flow stops. 

   The  filter is activated. The display shows 

SELECT  

   PRODUCT

.

K) Cleaning with Special Tablet

(Machine is on)

The message 

CLEAN MACHINE 

appears after 220

cups of coffee. This cleaning program removes coffee
oils inside the machine and takes less than 15 minutes.

Important

: Do not interrupt program once started.

Important

: Only use special round cleaning tablet.

SELECT PRODUCT/CLEAN MACHINE

1. Fill Water Tank and push and hold the 

RINSE

    button until 

EMPTY TRAY/EMPTY GROUNDS

.

2. Remove and empty the tray and the used coffee 

    container and replace. 
    

Attention:

You must remove the tray for 20 seconds

    even if it is empty. Replace tray. 

PRESS RINSE

3. Place a large container (24 oz.) underneath the 

    coffee spout and push the 

RINSE

button. 

    

MACHINE CLEANING

    Then 

ADD TABLET/PRESS RINSE

4.  Drop one white tablet  into the ground coffee funnel.
5. Push the 

RINSE

button. 

MACHINE CLEANING

    After a few minutes 

EMPTY TRAY/EMPTY 

    GROUNDS

.

6. Carefully lift, remove and empty tray and replace. 

    The display shows 

SELECT PRODUCT

.

7. Remove the funnel and rinse under hot water. 

    

L) Decalcifying  

DE-SCALE MACHINE

For different water hardness levels see Operating 
Instructions (chapter 15). If a water hardness level is
selected, the decalcifying monitor is active. The 
machine needs to be decalcified when above 
message appears. 

Important

: If you use the Clearyl filter and 

DE-SCALE

MACHINE

appears, then the Clearyl Activation 

procedure was not performed properly (see "I" above).

Important

: Decalcifying program must not be interrupted.

Use only the special decalcifying tablets (not the
cleaning tablets!). For supplies see other side.