Instruction manual Ri7305
Please keep this instruction manual for future reference
10
Instruction manual RiL1795
Please keep this instruction manual for future reference
23
min.
75mm
Ventilation space at
rear to allow heat
dissipation from the
condenser
Plinth ventilation
min. 200cm
2
Air flow
Air flow
min.
75
mm
VENTILATION REQUIREMENTS
The main consideration when installing a
refrigeration product into a cabinet is ventilation.
The heat removed from the appliance needs to
be dissipated into the room. Failure to correctly
ventilate the product can result in increased
running costs and premature failure. It will also
invalidate the guarantee provided with the
appliance.
An air intake in the plinth is required to allowfor
the correct air flow (recommended 500mm x
40mm). If preferred a decorative stainless steel
plinth grille is available, product code:
GRILL/SENSE600. This can be purchased from
your retailer or www.caple.co.uk.
To ensure the correct operation of the appliance
it is important the top of the housing is not
blocked off. The top of the cabinet needs to
be vented into the room, the recommended
minimum size of the vent opening is 500x40mm.
There should also be space at the rear of the
cabinet to allow the cool air to be drawn over the
condenser. This should also be at least 500mm
x 40mm. The more air available to circulate the
product, the more efficiently it will operate
RIL1795_Larder Instruction Manual.indd 23
07/02/2017 10:35
VENTILATION REQUIREMENTS
The main consideration when installing
a refrigeration product into a cabinet is
ventilation. The heat removed from the
appliance needs to be dissipated into the
room. Failure to correctly ventilate the
product can result in increased running costs
and premature failure. It will also invalidate
the guarantee provided with the appliance.
An air intake in the plinth is required to
allow for the correct air flow (recommended
500mm x 75mm). If preferred a decorative
stainless steel plinth grille is available, product
code: GRILL/SENSE600. This can be purchased
from your retailer or www.caple.co.uk.
To ensure the correct operation of the
appliance it is important the top of the
housing is not blocked off. The top of the
cabinet needs to be vented into the room,
the recommended minimum size of the vent
opening is 500x75mm.
There should also be space at the rear
of the cabinet to allow the cool air to be
drawn over the condenser. This should also
be at least 500mm x 75mm. The more air
available to circulate the product, the more
efficiently it will operate.