Connecting the feeder
cable
To connect the feeder cable to the cook-
er it is necessary to:
– Remove the two screws that hold
shield A behind the cooker.
– Open completely the cable clamp D.
– Insert the mains cable (type H05RR-F
or H05VV-F) of minimum 6 mm
2
sec-
tion into the cable clamp D.
– Connect the phase and earth cables
to terminal B according figure 1.3 and
1.4.
– Pull the feeder cable and block it with
the cable clamp D.
– Re-mount shield A.
N.B. The earth conductor must be left
about 3 cm longer than the others.
A
D
B
Fig. 1.2
PE
1 2 3 4 5
N (L
2
)
L
1
230 V
Fig. 1.3
Feedeer cable section
“Type H05RR-F or H05VV-F”
230 V
3 x 6 mm
2
(**)
(**)
– Connection with wall box con-
nection.
– Diversity factor applied.
– A diversity factor may be applied
to the total loading of the cooker
only by a suitable qualified person.
2
3
4
5
1
230 V ~
N(L
2
)
PE
L1
Red
or
Brown
(Live)
Black
or
Blue
(Neutral)
Green
and
Yellow
(Earth)
Fig. 1.4
PE
Earth
N
Neutral
L
Live