![Caple C990i Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/caple/c990i/c990i_instruction-manual_2553869023.webp)
23
•
Case 2:
Pan with power level [ 1 ] moves to an induction coil which is in operation already.
A power level conflict occurs:
o
Due to safety reasons the pan with the lowest power level has priority.
o
The power level of the pan (heated with power level [ 8 ]) is decreased to the max. possible power
level (here e.g. level [ 3 ]).
o
The pan shape shows an exclamation mark to indicate that there is a conflict.
•
Solution 2:
o
Move the pan within 10 seconds (away from the induction coil with a conflict). The originally set
power level (here e.g. level [ 8 ]) will be restored automatically.
o
Accept the reduced power level. The conflict message goes out of view after 10 seconds.
o
Reduce the difference in the power levels that are set for the pans.
•
Case 3:
Pan is put on an induction coil which is in operation already.
The pan with power level [ 9 ] is heated with induction coil 2, 4, 5 and 7.
If another pan (without power) is put on induction coils 3 and 4, then a conflict arises on induction coil 4.
Induction coil 4 may no longer supply any power now, because the power level requirement of the pan that was put
on the hob last, is [ 0 ].
•
Solution 3:
o
Set a power level for the pan that was put on the hob last.
o
Move the pan to another position on the hob.