15
Installation instructions
The installation comes under the exclusive responsibility of specialists.
The installer must respect the local legislation and the standards in their home country.
How to apply the gasket:
The gasket supplied with the hob avoids all infiltration of liquids into the cabinet.
The installation has to be done carefully, in conformity of the following drawing.
Fitting - installing:
The cut out size is as follows:
Model Cut-size
C875I
890 x 390 mm
Ensure that there is a distance of 50mm between the hob and the wall or sides.
The hobs are classified as “Y” class for heat protection. Ideally the hob should be installed with
plenty of space on either side. There may be a wall at the rear and tall units or a wall at one side.
On the other side, however, no unit or divider must stand higher than the hob.
The piece of furniture or the support in which the hob is to be fitted, as well as the edges of
furniture, the laminate coatings and the glue used to fix them, must be able to resist
temperatures of up to 100°C.
The mural rods or edge must be heat-resistant.
Do not install the hob to the top of a not ventilated oven or a dishwasher.
There must be a minimum ventilation space of 20mm from the base of the hob to any other
surface to ensure good air circulation for the electronic device (see image A below).
If a drawer is placed under the worktop, avoid putting into this drawer flammable objects (for
example: sprays) or non heat-resistant objects.
Materials which are often used to make worktops expand on contact with water. To protect the
cut out edge, apply a coat of varnish or special sealant. Particular care must be given to applying
the adhesive joint supplied with the hob to prevent any leakage into the supporting furniture.
This gasket ensures a correct seal when used in conjunction with smooth work top surfaces.
The safety gap between the hob and the cooker hood placed above must respect the indications
of the hood manufacturer. In case of absence of instructions respect a distance minimum of
760mm.
The connection cord should be subjected after building, with no mechanical constraint, for
example a drawer.
Stick the gasket (2) two
millimetres from the external
edge of the glass, after removing
the protective sheet (3).
Image A