background image

 

 

Gas category

 

I

3+ 28~30/37

 

BE, FR, IT, LU, IE, GB, GR, PT, ES, CY, CZ, LT, SK, CH, SI 

I

3B/P(30)

 

LU, NL, DK, FI, SE, CY, CZ, EE, LT, MT, SK, SI, BG, IS, NO, TR, HR, RO, IT, HU 

I

3B/P(37)

PL 

I

3B/P(50)

AT, DE, CH, SK 

I

2Lw

PL 

I

2Ls

PL 

I

2E+

BE, FR 

I

2H(20

 

FR, IT, BE, NL, DK, IE, GB, GR, ES, PT, AT, FI, SE CZ, EE, HU, LV, LT, SK, SI, IS, NO, 

I

2E(20)

 

DE, LU, PL 

Note: when injectors are changed, the new one should be marked by the gas technician. 

 

Appliance Class: 3 

This appliance complies with the following E.E.C. Directives: 2006/95, 93/68, 2004/108 and 90/396. 

 

Electric:   

BS plug (230 V 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.): 

GB, TR, CY, MT 

VDE plug

FR, BE, NL, GR, ES, PT, AT, FI, SE, CZ, EE, HU, LV, LT, SK, SI, IS, NO, TR, BG, HR, RO, DE, LU,PL, CY, 

MT  

Italy plug: IT

 

Swiss plug: CH 

Denmark plug: DK

 

(Pls see figure 8)

 

Important safety requirements 

 

Provision for ventilation 

The hob should not be installed in a bed sitting room with a volume of less than 20m . If it is installed in a room of volume less than 5m  

an air vent of effective area of 110cm is required. If it is installed in a room of volume between 5m and 10m

 an air vent of effective 

area of 50cm   is required, while if the volume exceeds 11m no air vent is required. However, if the room has a door which opens 

directly to the outside no air vent is required even if the volume is between 5m

 

and 11m

3

. If there are other fuel burning appliances in 

the same room, which should be consulted to determine the requisite air vent requirements.   

Location 

The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom, shower room or garage.   

Before making the cut out in the worktop ensures that there is a minimum distance of 55 mm between the rear edge of the hob and the 

wall. 

A minimum distance of 100 mm must be left between the side edges of the hob and any adjacent cabinets or walls.   

The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm.   

If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob.   

The minimum distance combustible material can be fitted directly above the hob is 700 mm. (See Figure 4*) 

Warning: The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. Ensure that 

Содержание C742G

Страница 1: ......

Страница 2: ...laced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children sho...

Страница 3: ... the control knobs are in the closed position when not in use When using other electrical appliances ensure the cable does not come into contact with the hot surfaces of the cooking appliance Unstable or misshapen pans should not be used on the hob as unstable pans can cause an accident by tipping or spillage Never leave the hob unattended when cooking with oil and fats Never use plastic or alumin...

Страница 4: ... burner efficiency you had better use pots and pans with a flat bottom fitting the size of the burner used see table Burner Minimum Diameter Maximum diameter Wok Large rapid Medium semi rapid Small auxiliary 240mm 180 mm 120 mm 80 mm 260mm 260 mm 220 mm 160 mm If you using a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle...

Страница 5: ...orrective action Check that the unit is plugged in and the electrical supply is switched on Check the mains fuse has not blown Check the burner cap and crown have been replaced correctly e g after cleaning The gas ring burns unevenly Check the main jet is not blocked and the burner crown is clear of food particles Check the burner cap and crown have been replaced correctly e g after cleaning Instr...

Страница 6: ...in a room of volume between 5m and 10m an air vent of effective area of 50cm is required while if the volume exceeds 11m no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5m and 11m 3 If there are other fuel burning appliances in the same room which should be consulted to determine the requisite air vent...

Страница 7: ...tely Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to RC 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough leak test is carried out on the hob and installation Ensure that the main connection pipe does not exert any strain on the hob When a...

Страница 8: ...port and front left burner cap and crown Fit manometer tube over the injector Turn on the burner gas supply and ignite another burner Turn off the burner supplies Conversion form NG to LPG or from LPG to NG Important The replacement conversion of the gas hob should only be undertaken by a competent person It is important to note that this model is designed for use with which gas category Please ch...

Страница 9: ...9 Figure 3 Figure 4 Figure5 Figure6 Figure7 Figure8 ...

Отзывы: