Instruction manual C4245
Please keep this instruction manual for future reference
15
Wiring and safety
The instructions given below MUST be adhered to during wiring:
- This appliance is designed to connect to 220-240V~ and is rated at 20Amps and
as such needs to be hard wired to the electrical supply.
- If the electrical supply is different from the value given above, call Caple Service
immediately.
- Wiring of the appliance must be performed by a qualified installer/electrician.
- The earth cable must be connected via the terminal screw with the earthing
mark. Supply cable connection must be as shown in the diagram. If there is no
earthed outlet conforming to regulations in the installation environment, the
installation cannot go ahead and an Electrician should be consulted immediately.
- The installation must include a suitable isolating switch with a minimum contact
opening of 3mm between the appliance and the mains. The isolating switch
should be sized according to the load on the rating plate “20Amp”and should
comply with current regulations.
- The earthed outlet must be in close vicinity of the appliance. Never use an
extension lead.
- The supply cable should not make contact with the product’s hot surface.
- In case of any damage to the supply cable, please call Caple Service. The cable
must be replaced by a qualified installer/electrician)
- Faulty wiring may damage the appliance. Such damage will not be covered by
the warranty.
- When wiring the terminal box care should be taken to fit and tighten the links on
the live and neutral terminals