background image

3/5

www.capitolindustriesinc.com

Function

Note

1.  Master Code Function

2. Sub-master Code Function

CE731

Electronic Pushbutton Cam Lock

Private Mode

Open 

8 digit master code

Set the master code

  --master code--#--01--#

--new master code--#--master code--#

Set the user code

--master code--#--02--#--4 digit new user code--#

--master code--#--03--#

Delete user code

Set or change

sub-master code
Delete sub-master code 

Set public mode 

  --master code--#--04--#

--8 digit new sub-master code--#

--master code--#--05--#

--master code--#--06--#

�明

Open 

8 digit master code

Set user code 

  --sub-master code--#--04--#--new sub-master code--#

--sub-master code--#--02--#--4 digit new user code--#

Set sub-master code

Function

Note

3. User Code Function

�明

Open 

4 digit user code

Set user code 

--user code--#--new user code--#

Function

Note

Re-lock automatically after 

3 seconds 

Re-lock automatically after 

3 seconds 

Re-lock automatically after 

3 seconds 

*

*

*
*

*

*

*

*

*

Operation

Operation

Operation

1-800-567-0451

Содержание CE731

Страница 1: ...s Succeed Green light will flash 2 times beep Low voltage Red light will flash 3 times with beep alarm inform user to replace the battery it could still allow to unlock for 100 openings In public mode Green light will flash on every 6 seconds Enter the code to lock the green LED light flashes at intervals indicating the lock or cabinet is in an occupied state Operate each button within 4 seconds o...

Страница 2: ...will flash 2 times beep Set 8 digit master code 06 Succeed Green light will flash 2 times beep User code is one time valid lock will keep open status until next user enter 4 digit code Factory settings 1 Private mode 2 User code 1111 3 Master code 20050330 8 digit Sub master code 8 digit Technician code 6 digit are without setting 4 Auto timed function is off 1 800 567 0451 ...

Страница 3: ...ub master code Delete sub master code Set public mode master code 04 8 digit new sub master code master code 05 master code 06 明 Open 8 digit master code Set user code sub master code 04 new sub master code sub master code 02 4 digit new user code Set sub master code Function Note 3 User Code Function 明 Open 4 digit user code Set user code user code new user code Function Note Re lock automaticall...

Страница 4: ...w master code Set or change sub master code master code 04 new sub master code master code 05 Delete sub master code Set private mode Set technician code Delete technician code Set automatic open lock Auto timed unlock off Set occupy light on Set occupy light off Set Auto timed unlock on Default setting 12h master code 07 master code 08 6 digit new technician code master code 09 master code 10 XX ...

Страница 5: ... 1 Penalty time Enter five incorrect codes will cause the lock shut down for 1 min 2 Emergency opening Open the protective cover insert the mechanical key to emergency opening the lock code still keep the previous setting pic 1 3 Initialize function Enter the operation and press the reset button on the back of lock pic 2 with 8 seconds green light flash with beep alarm locks go back to factory set...

Отзывы: