IMPORTANT : Sealing of the Gas Inlet Apertures
In line with current regulations,
it is imperative that the gas supply inlet aper-
ture that is utilised during the installation is sealed with the grommet
as supplied in the loose items pack
. The product is manufactured with 3 knock
out gas inlets in the firebox wrap to allow a left hand, right hand or rear gas inlet
supply to the inlet elbow. Using a hammer and a blunt chisel, remove the inlet
aperture selected and then seal with the grommet supplied. To provide access for
the gas supply pipe, cut the grommet with a sharp knife. Failure to seal the inlet
apertures could lead to flame reversal, which in turn will damage the burner and
control systems of the product.
Fig. 8 below shows a correctly sealed installation.
Fig. 8
PLEASE NOTE :-
BFM EUROPE LTD. WILL NOT BE LIABLE FOR
GUARANTEE CLAIMS THAT ARE AS A DIRECT
RESULT OF THE GAS INLET APERTURE NOT BEING
CORRECTLY SEALED WITH THE GROMMET
PROVIDED.
Grommet fitted and cut to
provide access for the gas
supply pipe.
14