INSTALLATION 

 
Once the installation is complete, the installer must advise the householder on 
the correct use of the stove and warn them to use only the recommended fuels 
listed in this document.  The installer must also advise the householder on the 
actions to be taken should smoke or fumes be emitted from the stove. 
 
This stove must not share a chimney with any other appliance 
 
Where the chimney is believed to have previously served an open fire 
installation it is possible that the higher flue gas temperature from a closed 
appliance may loosen deposits that were previously firmly adhered, with the 
consequent risk of flue blockage.  It is therefore recommended that the chimney 
be swept a second time within a month of regular use after installation. 
 
Check the chimney is in good condition, dry, free from cracks, leaks and 
obstructions. The diameter of the flue should be no more than 230mm.  If this 
cannot be met then an appropriate liner should be fitted by a suitably approved 
method. 
 
A 125mm flue liner may be used in accordance with the Building Regulations.    
The chimney and connecting flue pipe should not narrow to less than the size of 
the outlet socket (collar) of the stove at any point.  It is essential that only 
recommended fuels are used – see page 15 for more information. 
 
The chimney height and the position of the chimney terminal must conform to 
Building Regulations and the latest edition of BS EN 15287-1:2007, Design, 
Installation and Commissioning of Chimneys should be followed. 
 
A flue draught of minimum 12 Pascals is required for satisfactory appliance 
performance.  The flue draught should be checked under fire at high output and 
if it exceeds 25Pa, a draught stabiliser may be required so that the rate of 
burning can be controlled, and to prevent possible over-firing. 
 
If you have any doubts about the suitability of your chimney, consult your local 
dealer/stockist.  He will also be able to provide advice about the possible need 
for a specialist cowl. 
 
 

Содержание AVEBURY

Страница 1: ...LLERS PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER Stoves operate at very high temperatures All persons including children and the infirm should be warned of this and not allowed to touch any surfac...

Страница 2: ...2 AVEBURY ECO SCENE ECO BASSINGTON ECO STANDARD LEGS BASSINGTON ECO SKIRTED LEGS BASSINGTON ECO BASELINE LEGS SIGMA ECO VEGA EDGE 200SL ECO...

Страница 3: ...DIMENSIONS OUTPUT EFFICIENCY PAGE 04 INSTALLATION PAGE 05 OPERATION PAGE 11 GENERAL MAINTENANCE PAGE 17 SAFETY NOTES TROUBLESHOOTING PAGE 19 STOVE ACCESSORIES PAGE 22 COMPONENT PARTS PAGE 23 TECHNICA...

Страница 4: ...m 615mm 80mm 317mm 114mm 324mm 364mm 443mm 575mm 530mm SCENE ECO 485mm 635mm 95mm 327mm 114mm 324mm 352mm 456mm 595mm 504mm SIGMA ECO 500mm 645mm 105mm 313mm 114mm 322mm 369mm 468mm 605mm 536mm VEGA E...

Страница 5: ...SUPPLIERS ACCEPT NO RESPONSIBILITY IF THIS ADVICE IS NOT FOLLOWED THIS APPLIANCE HAS BEEN EXTENSIVELY TESTED FOR SAFETY AND EFFICIENCY DO NOT ATTEMPT TO MODIFY IT ALWAYS USE GENUINE REPLACEMENT PARTS...

Страница 6: ...an 230mm If this cannot be met then an appropriate liner should be fitted by a suitably approved method A 125mm flue liner may be used in accordance with the Building Regulations The chimney and conne...

Страница 7: ...on remove the baffle plates bricks and door Place in a secure place to avoid damage Refit after installation Upon completion of installation the appliance should be checked under fire for soundness of...

Страница 8: ...fully set the stove upright and check that all internal components are correctly positioned Clearances If the stoves are to be installed adjacent to materials that can catch fire like wood then the fo...

Страница 9: ...l the stove and secure the hearth If existing floors do not have adequate load bearing capacity then suitable modifications must be adopted When the stove is in the desired position fix the brackets p...

Страница 10: ...ing with a flue draft stabiliser into houses built before 2008 at least 1500mm 2 additional means of permanent ventilation direct to outside is required Houses built after this date will require addit...

Страница 11: ...11 OPERATION SLIDING PRIMARY AIR CONTROL TYPE ROTARY PRIMARY AIR CONTROL TYPE Secondary Air Control Riddling Mechanism Primary Air Control Secondary Air Control Riddling Mechanism Primary Air Control...

Страница 12: ...hracite fires It should be closed when a wood fire is established for the best efficiency Secondary Air Secondary air is controlled via the sliding vent above the door it is this airwash that keeps a...

Страница 13: ...low the fuel to reach a steady glow and build up the fire gradually Once you have a good fire established across the fire bed further fuel can be added as required When your fire is well established y...

Страница 14: ...e and prevent efficient burning Solid fuel produces ash which if allowed to build up will stifle the air flow through the grate and eventually cause the fire to die Caution only empty the ash pan when...

Страница 15: ...Approval does not cover the use of other fuels either alone or mixed with the recommended fuels listed above nor does it cover instructions for the use of other fuels Wood Only kiln dried or well sea...

Страница 16: ...r Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any...

Страница 17: ...g can cause excess smoke Operation with door left open Operation with the door open can cause excess smoke The appliance must not be operated with the appliance door left open except as directed in th...

Страница 18: ...avoid accidental damage Inner Grate Removal and Replacement Remove the ash pan and detach the riddling arm from the underside of the circular inner grate Lift the inner grate vertically and manoeuvre...

Страница 19: ...ppliance should be cleaned again and the chimney swept it is essential to have the chimney swept at least once annually and it is recommended that it is swept twice a year Safety Notes and Troubleshoo...

Страница 20: ...eject and safely dispose of fuel from the appliance 3 Check for a flue blockage and clean if required Do not attempt to relight the fire until the cause has been identified and corrected If necessary...

Страница 21: ...fuels vary in heat value check with your coal merchant as to suitability Dirty Glass Nearly always caused by poor fuel quality check the moisture content of the wood you are burning with a moisture me...

Страница 22: ...e to supply Matching graphite high temperature paint Stove Glass Cleaner Spare Rope Rope Seal Adhesive CO Detector Stove Fan Stove Thermometer Wood Moisture Meter Spare Glove Permanent Ventilators Pur...

Страница 23: ...p panel FFVE4003 18 Stove bottom panel FFVE3002 5 Secondary air control plate FFVE2023 19 Ash Pan FFVE2014 6 Flue collar FFVE008CE 20 Primary air slide plate FFVE2020 7 Baffle plate FFVE3007 21 Stove...

Страница 24: ...23 19 Ash Pan FFVE2014 Secondary air control plate WW FFVE5023SC 6 Flue collar BLACK FFVE008 20 Primary air slide plate FFVE2020 Flue collar WW FFVE008CE 7 Baffle plate FFVE3007 21 Stove tool FFVE029...

Страница 25: ...3 19 Ash Pan FFVE2014 Secondary air control plate WW FFVE5023SC 6 Flue collar BLACK FFVE008 20 Primary air slide plate FFVE2020 Flue collar WW FFVE008CE 7 Baffle plate FFVE3007 21 Stove tool FFVE029 8...

Страница 26: ...3 19 Ash Pan FFVE2014 Secondary air control plate WW FFVE5023SC 6 Flue collar BLACK FFVE008 20 Primary air slide plate FFVE2020 Flue collar WW FFVE008CE 7 Baffle plate FFVE3007 21 Stove tool FFVE029 8...

Страница 27: ...egs FFVE7010 4 Stove top panel FFVE7003 17 Outer grate FFVE3005 5 Secondary air control plate FFVE7023 18 Stove bottom panel FFVE7002 6 Flue collar FFVE008CE 19 Ash Pan FFVE2014 7 Baffle plate FFVE300...

Страница 28: ...FFVE3007 16 2 x bottom fire brick FFVE4042 4 Stove top panel FFVE7003 17 Ash Pan FFVE2014 5 Rear fire brick FFVE2013 18 Glass panel FFVE4018 6 Stove rear panel FFVE3034 19 Stove tool FFVE029 7 Flue bl...

Страница 29: ...econdary air control plate WW FFVE2023BSC 6 Flue collar BLACK FFVE008 20 Primary air slide plate FFVE2020 Flue collar WW FFVE008CE 7 Baffle plate FFVE3007 21 Stove tool FFVE029 8 Heat shield FFVE2032...

Страница 30: ...DEMARK PERCY DOUGHTY CFL 2 MODEL IDENTIFIER BASSINGTON ECO 3 ENERGY CLASS A 4 DIRECT HEAT OUTPUT 5 0kW 5 INDIRECT HEAT OUTPUT N A 6 ENERGY EFFICIENCY INDEX 112 0 7 ENERGY EFFICIENCY AT NOMINAL HEAT OU...

Страница 31: ...EFFICIENCY INDEX 112 0 7 ENERGY EFFICIENCY AT NOMINAL HEAT OUTPUT 84 0 8 SPECIFIC PRECAUTIONS SEE MANUAL 1 SUPPLIER NAME OR TRADEMARK PERCY DOUGHTY CFL 2 MODEL IDENTIFIER VEGA EDGE 200SL ECO 3 ENERGY...

Страница 32: ...el 01204 868 550 Fax 01204 868 551 Email sales percydoughty com Website www penmancollection co uk For South of England Sales please contact Capital Fireplaces Ltd Unit 12 17 Henlow Trading Estate Hen...