Capital fireplaces Sirius 490MF Скачать руководство пользователя страница 14

Sirius MF&WD Version 1 November 2013 

 

Inner Grate Removal and Replacement 

 
Lift the inner grate vertically until it clears 

the locating pin of the riddling 

mechanism housed in the ash pan chamber, 

then manoeuvre the grate out of the 

stove.  When replacing, ensure the slot 

engages with the pin. 

 

Outer Grate Removal and Replacement 

 
Remove all the bricks and the inner grate.  

Lift the outer grate up at an angle 

left higher than right and manoeuvre the grate out left side first.  There is always a knack to such a task, but it is easy 
once learnt! 
 

Stove Body 

 
The stove is finished with a heat-resistant paint and this can be cleaned with a soft brush.  Do not clean whilst the stove 
is hot, wait until it has cooled down.  The finish can be renovated with Capitalstove paint available from your supplier. 
 

Glass Panels 

 
Clean the glass panels when cool with Capital glass cleaner.  Highly abrasive substances should be avoided as these can 
scratch the glass and make subsequent cleaning more difficult.  Wet logs on heated glass, a badly aimed poker or heavy 
slamming of doors could crack the glass panels.  The glass will not fracture from heat. 
 
Should a glass panel require replacement, then 

remove the four screws and clips 

retaining the glass frame, carefully remove the 

broken glass and replace the panel with 

the correct stove glass from your supplier.  

Ensure you use new glass fibre seal 

around its edge, and use the steel frame, clips 

and screws to retain it in position. 

 
 
Seasonal Maintenance 

 
If your stove is be unused for any length of 

time, e.g. summer months, then it is 

recommended that it is cleaned out 

thoroughly.  Air slides should be lightly 

oiled with WD40 or similar and left partially 

open to allow air circulation.  Regular 

monitoring of the inside components will identify condensation or water ingress.  If these problems occur, then your 
stove needs to be dried and the cause of the problem rectified.  After a shut down, and before reuse, the appliance 
should be cleaned again and the chimney swept, it is essential to have the chimney swept at least once annually and it 
is recommended that it is swept twice a year. 

 
Safety Notes and Troubleshooting 

 

IT IS ESSENTIAL AND REQUIRED BY BUILDING REGULATIONS THAT A CO ALARM IS INSTALLED IN THE SAME ROOM AS 
THIS APPLIANCE 

 

Fires Can Be Dangerous 
 

Always use a fire guard to BS 8423:2002, Fireguards for Use With Solid Fuel Appliances, in the presence of children, the 
elderly or the infirm.  Inform all persons of the dangers of high temperatures during operation of appliance including 
the stove pipe. 
 
Do not use this stove as an overnight burner, when finished for the evening, leave the air controls open to allow the 
remainder of the fuel to burn out. 
 
Use the glove provided to open the door.  Never empty the ash pan when hot. 
 

Do Not Over-Fire 

 

Содержание Sirius 490MF

Страница 1: ...uding children and the infirm should be warned of this and not allowed to touch any surfaces whilst in use The operator must use the glove provided The following is a list of stove accessories your retailer will be able to supply Capital matching graphite high temperature paint Stove Glass Cleaner Spare Rope Rope Seal Adhesive CO Detector Capital Stove Fan Capital Stove Thermometer Wood Moisture M...

Страница 2: ...nds Variations may occur due to installation atmospheric conditions and fuel quality LIFETIME GUARANTEE All Sirius Stoves are covered by a lifetime guarantee valid for original purchases only from date of sale This guarantee excludes the following naturally wearing consumable items Door Glass Firebricks Rope Seals Baffle Grate including riddling system In addition the following criteria must be me...

Страница 3: ... CONTACT WASH IMMEDIATELY WITH PLENTY OF WATER ASBESTOS THESE STOVES CONTAIN NO ASBESTOS IF THERE IS A POSSIBILITY OF DISTURBING ANY ASBESTOS IN THE COURSE OF INSTALLATION THEN PLEASE SEEK THE GUIDANCE OF A SPECIALIST AND USE APPROPRIATE PROTECTIVE EQUIPMENT METAL PARTS WHEN INSTALLING OR SERVICING THIS STOVE CARE SHOULD BE TAKEN TO AVOID THE POSSIBILITY OF PERSONAL INJURY UNLESS THE INSTALLER IS ...

Страница 4: ...uld be followed A flue draught of minimum 12 Pascals is required for satisfactory appliance performance The flue draught should be checked under fire at high output and if it exceeds 25Pa a draught stabiliser may be required so that the rate of burning can be controlled and to prevent possible over firing If you have any doubts about the suitability of your chimney consult your local dealer stocki...

Страница 5: ...Sirius MF WD Version 1 November 2013 Typical Installation for Inglenook Fireplaces rear flue Side View Sirius 790 Sigma MF shown Closure or register plate Sirius 790 Scene MF shown ...

Страница 6: ...e flue pipe must not exceed the flue outlet diameter on the stove It is essential that all connections between the stove and chimney flue are sealed and made airtight Both chimney and flue pipe must be accessible for cleaning and if ALL parts of the chimney cannot be reached through the stove a soot door must be fitted to enable this to be done Sirius 490 Sigma MF shown Typical Installation Into I...

Страница 7: ...k and using the screws provided fit the legs in place Carefully set the stove upright and replace the internal components The following information applies to all variants of the Sirius 490MF Sirius 490WD Sirius 790MF and Sirius 790WD stoves Clearances If the stoves are to be installed adjacent materials that can catch fire like wood then the following clearances must be adhered to STOVE BACK mm S...

Страница 8: ...is purpose must not be restricted or blocked Flues Without a Flue Draft Stabiliser When installing the Sirius 490 stoves without a flue draft stabiliser into houses built before 2008 no additional permanent ventilation will be required Houses built after this date will require additional means of permanent ventilation direct to outside of at least 2750 mm2 Capital Vents can be used for this When i...

Страница 9: ...r rear flue installations Replace the rear heat shield Remember to fit the blanking plate to the unused flue position if it has been removed Sirius 790 Sigma MF shown Dimensions DIM mm SIRIUS 490 MF SIRIUS 490 WD SIRIUS 790 MF SIRIUS 790 WD SIGMA SCENE SIGMA SCENE SIGMA SCENE SIGMA SCENE A 573 568 573 568 630 630 630 630 B 474 451 474 451 578 551 578 551 C 225 213 225 213 275 265 275 265 D 460 468...

Страница 10: ...air controls open can cause excess smoke These stoves must not be operated with air controls open except as directed in these instructions Lighting the Stove It is essential that you have three or four small fires before you operate the stove to its maximum heat output This is to allow the paint to cure and to temper your cast iron stove We recommend this running in procedure after long shutdowns ...

Страница 11: ...primary air control about half to three quarters open and the secondary air control fully closed Do not overload Once established and for the best results from your Sirius 790MFstove load about 1 kg of anthracite or equivalent per hour with the primary air control about half to three quarters open and the secondary air control fully closed Do not overload Of course best burning depends on the type...

Страница 12: ...or Environment Food and Rural Affairs has powers to authorise smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for...

Страница 13: ...es on the back firebricks tertiary air plenum and side firebricks so note its position before removal To remove lift plate and bring forwards dropping the left side as you bring it forwards Tilt it at an angle to withdraw it left side first from the front of the stove It may help to remove the left side brick To replace position baffle plate on back and right side brick lift plate and replace rema...

Страница 14: ...l with the correct stove glass from your supplier Ensure you use new glass fibre seal around its edge and use the steel frame clips and screws to retain it in position Seasonal Maintenance If your stove is be unused for any length of time e g summer months then it is recommended that it is cleaned out thoroughly Air slides should be lightly oiled with WD40 or similar and left partially open to all...

Страница 15: ...and must NOT be tolerated A list of Qualified Engineers is available from UK Solid Fuel Association R o I 7 Swanwick Court Irish National Fireplace Organisation Alfreton 162 Chapel Street Derbyshire Dublin DE55 7AS Ireland Tel 0845 601 4406 Tel 01 801 5959 Chimney Fire Identified by loud roaring sounds dense smoke and sparks exiting chimney Shut down all air supply to stove by closing air vents en...

Страница 16: ...ese will scratch the glass making tar build up harder to remove NEVER spray aerosols near the appliance when it is alight Un burnt Fuel Insufficient air reaching fuel Adjust the air controls to supply combustion air to burn fuel fully Check if the ash pan is full empty if required Front bar fret may be blocked de ash Check for jammed clinker or nails in grate when the fire is out and cold Componen...

Страница 17: ... 12 BAR LOG RETAINER 13 INNER GRATE 14 OUTER GRATE 15 ASH PAN 16 LEFT AND RIGHT BOTTOM BRICKS 17 BOTTOM CASTING 18 RIDDLING MECHANISM 19 RIDDLING ACTUATOR 20 LEGS 21 LEFT SIDE BRICK 22 RIGHT SIDE BRICK 23 BAFFLE SUPPORT BRACKET 24 BACK LEFT RIGHT AND TOP 790WD ONLY BRICKS 25 COLLAR 26 TOP CASTING 27 SECONDARY AIR CONTROL ASSEMBLY 28 BAFFLE 29 BAFFLE TOP SUPPORT BRACKET 30 THROAT PLATE 31 BLANKING ...

Страница 18: ...Sirius MF WD Version 1 November 2013 Capital Fireplaces Limited Unit 12 17 Henlow Trading Estate Henlow Camp Herts SG16 6DS 01462 813138 ...