Starting from the detection of the presence of the key, the LED performs periodic 

AMBER

 flashes at a rate of one every 2 seconds. 

At each flash of light a different command is associated, to confirm the command you need, remove the 

WineCapKey

 immediately 

after flash corresponding to the  desired command. The 

TEST

 corresponds to the  second pulse and activate the "

Field

 

Measurer

function.

 

 

The 

datalogger

 will give back the radio signal quality through led flashes: 

LED FLASHES 

RADIO SIGNAL QUALITY 

 

5 green flashes 

Excellent 

 

4 green flashes 

Good 

 

3 green flashes 

Fair 

 

2 amber flashes 

Sufficient 

 

1 red flash 

Insufficient 

 

1 red flash, 2 seconds 
long 

Out of range – network 

search 

Picture 5 - Radio signal quality

 

Optimize reception selecting the best position: small movements can help. 

If  the  signal  is  absent  or  insufficient  at  the  install  point,  a 

WR12

 

router

  should  be  put  between  (

refer  to  "WineCapManager

 

User 

Manual

). The 

router

 itself must be located in a position where the signal level is at least sufficient. 

The network will reconfigure itself automatically; the signal will be good again when the 

datalogger

 synchronizes with the 

router

The link will not be reconfigured until completely lost by the 

datalogger

. Because of this, in some cases it could be necessary to 

force  the  operation.  In  such  cases,  put  the 

datalogger

  in 

STANDBY

  mode,  the  run  the 

TEST

  again  (

refer  to  "WineCapManager"  User 

Manual

). 

NOTE

: The display equipped 

datalogger

 (

WD04T

) is recommended, as reading the signal quality is made easier with this model. 

 

6.

 

Stand alone USB datalogger installation. 

Install the 

datalogger

 in appropriate place. 

If the sampling process has not yet been activated you can start it through the 

WineCapKey

.  

Bring  it  closer  to  the  sensitive  point,  wait  for  2  flashes  (

TEST

)  and  remove.  The 

datalogger

  begins  sampling  according  to  your 

settings through your PC. 

Through the 

WineCapKey

 is possible to ask for the current status, bring it close to the 

datalogger

 for 1 flash (

STATE

) and remove it. 

 

 

Содержание WSD12T-AV

Страница 1: ...on the PC connected to the basestation that will be coupled with the datalogger USB Datalogger Mode for this operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the datalogger s operation mode The sampling interval must be set with the datalogger in STAND ALONE mode and automatically the datalogg...

Страница 2: ...AV User Manual Picture 2 Datalogger positioning 3 Wireless dataloggers user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a command user must approach the WineCapKey to the datalogger s sensible area and keep it in that position the following picture Fig 3 shows datalogger s sensible points Picture 3 WineCapKe...

Страница 3: ...ORY RESET The device performs the memory deleting procedure and goes in STOP status All samples configuration and wireless network data associated are LOST To reactivate the device a new association and configuration procedure is necessary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command execution the led flashes as the PROBE DATALOGGER NO...

Страница 4: ...ts can help If the signal is absent or insufficient at the install point a WR12 router should be put between refer to WineCapManager User Manual The router itself must be located in a position where the signal level is at least sufficient The network will reconfigure itself automatically the signal will be good again when the datalogger synchronizes with the router The link will not be reconfigure...

Страница 5: ...he datalogger If the device is shut off and left unused for a long time you can issue the STANDBY command Its corresponds to the command number 4 and must be issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture and wait for four AMBER flashes then remove the WineCapKey from datalogger Verify that the datalogger asks for confirmation of STANDBY command with...

Страница 6: ...rehousing 40 C 70 C Radio frequency ISM 868MHz Radio coverage From 800m up to 12 8Km on sight Sealing IP65 Dimensions 90 x 120 x 25mm Weight 350g Case material ABS Mounting Fix on 4 points Connections Wireless USB Cable external diameter 4 7mm maximum Copper wire section 0 05 2 5mm 14 AWG Temperature Transducer type NTC10KΩ Temperature Measure range 10 C 60 C Temperature Measure accuracy 0 2 C in ...

Страница 7: ...ONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 7 8 WSD12T AV User Manual 10 Mechanical dimensions Picture 8 Mechanical dimensions ...

Страница 8: ...e 2011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception poi...

Отзывы: