TFC Hydraulic 

Connection Kit 6859795 

for Crown RC5500 Truck

This manual provides instructions for Cascade TFC™ 

Hydraulic Connection Kit 6859795 for Crown RC5500 Truck.  

The kit includes a manifold, mounting hardware, hoses and 

fittings.

1

  Make sure all other (non-TFC) clamp system relief valves 

are removed or adjusted out of the system by setting them 

to their maximum setting.

2

  Disable the driver clamp pressure selection option and 

make sure that system pressure for the auxiliary clamp 

circuit is set to maximum pressure (2300 psi minimum). 

3

  Verify that the auxiliary clamp circuit flow is set to between 

10 gpm and maximum flow.

4

  Mount the TFC valve on the chassis inside left wall above 

the wheel.  Position the valve with the coil to the back and 

TANK port on top.  Use the supplied M8 fasteners.  

 

NOTE:

  It is easiest to connect the valve driver and 

electrical harness to the coil at this time.

 

NOTE:

  The mast hose in this kit is for most 154 in./71in. 

lift/collapsed masts and it replaces Crown hose Part 

No. 064362-024.  For other mast heights, consult Crown 

Engineering.

Installation