Capelec CAP2600 Скачать руководство пользователя страница 34

 

 

 

Содержание CAP2600

Страница 1: ...Rev A 1130 rue des Marels FR 34000 MONTPELLIER Phone 33 0 467 156 156 Fax 33 0 467 224 224 e mail contact capelec fr www capelec fr USER MANUAL CAP2600 WORKSHOP Expert Universal headlight beam tester ...

Страница 2: ......

Страница 3: ... 2 5 Customising and entering the garage header 10 Section 2 USER MANUAL 11 I Overview 11 II Positioning the CAP2600 Workshop 14 2 1 Vehicle preparation 14 2 2 Positioning in the vehicle length axis 15 2 3 Positioning the optical block in front of the headlamp 16 III Lamp inspection 17 3 1 Inspection sequence 17 3 2 Expert report 23 3 3 Advice when using the expert function 27 IV Configuration 28 ...

Страница 4: ... vehicles with a gross vehicle weight of less than 3 5 tonnes Please read this manual carefully before using the CAP2600 WORKSHOP Keep it in a safe place to be able to consult it if necessary Note The information in this document is subject to change without notice CAPELEC cannot be held liable for direct or indirect damage of any type nor for losses or costs incurred through non compliant use WAR...

Страница 5: ... define a work zone and qualify it It features innovating and unique technology the ANYWHERE ground compensation system The CAP2600 WORKSHOP can therefore be used anywhere in your workshop II Installation and commissioning 2 1 Assembly instructions The CAP2600 WORKSHOP is delivered assembled and calibrated Unpacking the CAP2600 WORKSHOP ...

Страница 6: ...7 19 Rev A Page 4 Cut the collar and keep the rubber stop Caution do not allow the metal cable to slip into the column Attach the metal cable onto the optical block Screw the upper stop to the top of the column ...

Страница 7: ... be used with or without a computer connection If you want to connect your device you can do so via the CAPELEC router or via your own WIFI network Connection to the preconfigured CAPELEC router The CAP2600 WORKSHOP is delivered with a router configured for automatic WIFI connection as an option It is used to access the WEB interface and generate the expert report Connect the router to the compute...

Страница 8: ...Edit 30 07 19 Rev A Page 6 Start the CAP2600 WORKSHOP The WIFI icon 1 and the WEB interface address 2 appear on the home page Open a web browser and enter the displayed address 1 2 ...

Страница 9: ...IFI network The CAP2600 WORKSHOP can be connected to your WIFI network It is used to access the WEB interface and generate the expert report Start the CAP2600 WORKSHOP Go to Config Link and enter the password 2345 Go to Web server and enter your SSID and key Bookmark this page ...

Страница 10: ... configuration otherwise switch to static IP by unchecking IP AUTO and enter an IP address Restart the CAP2600 WORKSHOP The WIFI icon 1 and the WEB interface address 2 appear on the home page Open a web browser and enter the address Add this page to the favourites 1 2 ...

Страница 11: ...WORKSHOP headlamp beam tester can be used without a connection The built in thermal printer makes it possible to print simplified reports Start the CAP2600 WORKSHOP Go to Config Link and enter the password 2345 Select Printer Restart the CAP2600 WORKSHOP Bookmark this page ...

Страница 12: ...0 2 5 Customising and entering the garage header From the headlamp beam tester Go to Config Company name and enter your company name From the WEB interface Go to Settings and enter the company name in the header and add the logo ...

Страница 13: ...ction 2 USER MANUAL I Overview 1 1 Touch screen display For optimum use the use of the stylus is recommended Battery charge level WIFI Signal USB memory Turn off the machine Inclinometer function Quick restart WEB interface address ...

Страница 14: ...e lateral angle and light intensity measurement High beam It is used to adjust the high beam dip angle lateral angle and light intensity measurement Fog lamps It is used to adjust the fog lamps dip angle and light intensity measurement AFS calibration It is used to calibrate the AFS function A specific diagnosis tool is required to interact with the calculator Configuration This menu gives access ...

Страница 15: ...It must remain accessible A charger different from the originally supplied charger must not be used under any circumstances BATTERIES The batteries must be replaced using original parts Recycle the batteries in compliance with the laws and regulations applicable to your country Do not dispose of them in the wild or in a dustbin Depending on regulations it may be prohibited to incinerate bury or di...

Страница 16: ...on the load When the vehicle is fitted with an adaptive lighting system AFS deactivate it by selecting dipped beams When the vehicle is fitted with a headlamp cleaning system check its operation and clean the insert if necessary For heavy goods vehicles Vehicle preparation Before the inspection Set the load compensation system to the appropriate position Disable the AFS Clean the headlamp inserts ...

Страница 17: ...er nozzles if their base is not deformed Pivot the box to place the laser line on the selected fixed points on the vehicle Start the measurement procedure During this phase you will move the CAP2600 WORKSHOP in front of the headlight while keeping the angle obtained with the laser It is advisable to check its position in relation to the vehicle between each lamp WARNINGS Laser radiation Class 2M l...

Страница 18: ...e screen guide the user When the optimum position is reached validated is displayed The CAP2600 WORKSHOP automatically moves to the next step The work method 1 Place the headlamp adjustment system in front of the headlamp below the centre of the lamp 2 Follow the instructions on the screen to align the optical block at the correct height 3 Place the optical block taking into account the assistance...

Страница 19: ...ion sequence In the start menu the CAP2600 WORKSHOP will guide you through the entire headlamp inspection process The sequence of steps is described in the following section Step 1 Enter the vehicle registration plate From the WEB interface enter the vehicle registration plate 1 and click Send 2 The plate appears on the headlight beam tester screen and in the vehicle to be processed column Validat...

Страница 20: ...ition the ANYWHERE modules as close as possible to the vehicle wheels on the left side as shown below Module A laser on the front wheel and module B target on the rear wheel To activate the module A laser press the switch for 2 seconds Point it to the module B target line Press the switch again to validate The laser flashes 3 times and sends the measurement Then it turns off automatically ...

Страница 21: ...even you can make an additional measurement on the right side of the vehicle Repeat the same operation on the right side by turning the laser around Click to activate the left right double measurement Confirm by pressing Measured slope on the left side Measured slope on the right side ...

Страница 22: ...hout having to repeat a measurement using the ANYWHERE module confirm by pressing Step 3 Choice of the headlamp height You must select the headlight height Position the CAP2600 WORKSHOP in front of the headlight inserts See section II The displayed height is expressed in metres It is obtained by measuring the distance between the ground and the lower edge of the headlight reflector Headlight infor...

Страница 23: ...e headlight insert to an accuracy of 5cm Select the height range and confirm by pressing Step 4 Checking dipped beam lamps To inspect the headlights right and left align the CAP2600 WORKSHOP in front of the headlight inserts See section II h 80 cm Headlight information to be measured ...

Страница 24: ...rinter by clicking You can send the results to the WEB interface by clicking You can access the inspection report assessment in the completed vehicles column R L I Validate the measurement Display the headlight image Screen rotation adjustment mode Back to positioning assistance Display of recorded images Data sent to the WEB interface Result ticket printed on a thermal printer ...

Страница 25: ...onnections It indicates the CAP2600 WORKSHOP home page address The vehicles processed during the day are accessible in the completed vehicles column Older vehicle results are grouped together in the Archives folder By default the expert report is composed of two technical and client reports You can download the reports in PDF format by clicking Archive or print them by clicking Print ...

Страница 26: ...on as well as work advice in the actions column The customer report This is a simplified and user friendly presentation of the lighting inspection result It is intended for the customer the driver The right column shows the lighting on the newly tested vehicle while the left column shows the optimum lighting ...

Страница 27: ...actory Geometry and adjustment quality Adjustment compliant Adjustment too low Adjustment too high with risk of dazzling Light intensity and safety Representation of the lighting distance Adjustment quality Representation of light intensity and colour temperature Inspection and free comments ...

Страница 28: ...ence Colour temperature and lamp quality Warm light White light Cold light Before after expert report When you expertise the same vehicle a second time following a repair for example three versions of the BEFORE AFTER report can be printed User detailed and technical Customer simplified and didactic Before after didactic and dynamic ...

Страница 29: ...arrying out a first dipped beam headlamp inspection in order to present the customer report to the customer If a defect is found you will be able to argue or justify the work The technical report will guide the work Following the work for example adjustment lamp replacement etc a second inspection linked to the first will make it possible to provide the client with a complete before and after serv...

Страница 30: ...ected Connection password 2345 Company name Used to record the company name address and other information This data will then appear on the printed ticket headers Date time Access date and time settings Inspection direction Used to select the order in which the headlamps are tested Right headlamp first then left right left or the opposite left right Standby sub menu Used to configure the standby a...

Страница 31: ... approved companies V Care and maintenance recommendations Lens maintenance Avoid soiling it with splashes or by touching it Clean when necessary using soapy water or a window cleaning product and a clean cloth If it is altered cracked or scratched report it to the maintenance company Battery maintenance If the autonomy decreases significantly report it to the maintenance company Mechanical checks...

Страница 32: ...ature from 5 C to 40 C Storage temperature from 15 C to 55 C Relative humidity 98 non condensed Specifications Dip angle measurement headlamp dipped angle in Dip angle measurement range from 6 to 6 Accuracy 0 2 Lateral angle measurement range from 10 to 10 Accuracy 0 2 Light intensity in lx Intensity measurement range from 0 to 200lx Accuracy 10 Operating distance 20 cm 80 cm Inclinometer Dip angl...

Страница 33: ... of the same type as the product being disposed of Any failures to respect these recommendations on the disposal of this type of waste can have negative effects on the environment and public health because these electric and electronic products generally contain potentially hazardous substances In parallel your complete collaboration in the correct disposal of this product will contribute to a bet...

Страница 34: ......

Отзывы: