CDE500 Vector Control AC Drive
Chapter 5 Parameter List Table
-87-
EA External Brake
Function
Code
Name
Range
Default
Step
Description
EA.00
①
External brake control enable
0~1
0
1
0: Inactive
1: active
EA.01
①
External brake off frequency limit
0.00~10.00
2.50
0.01Hz
EA.02
①
External brake off current limit
0.0~180.0
110.0
0.1%
EA.03
①
External brake off delay time
0.00~10.00
0.50
0.01Sec
EA.04
①
Acceleration pause time for external
brake off
0.00~10.00
1.00
0.01Sec
EA.05
①
External brake on frequency limit
0.00~10.00
2.00
0.01Hz
EA.06
①
External brake on waiting time
0.00~10.00
0.00
0.01Sec
EA.07
①
Stop delay time after external brake
on
0.00~10.00
1.00
0.01Sec
Eb Supervision
Function
Code
Name
Range
Default
Step
Description
Eb.00
①
Timing function
0~1
0
1
0: Inactive
1: Active
Eb.01
①
Timing duration source
0~3
0
1
0: Eb.02
1: AI1
2: AI2
3: AI3
Eb.02
①
Timing duration
0.0~6500.0
0.0
0.1Min
Eb.03
①
Current running time
reached threshold
0.0~6500.0
0.0
0.1Min
Eb.04
Accumulative power-on
time(day) threshold
0~9999
0
1Day
Eb.05
Accumulative power-on
time(hour) threshold
0.00~23.99
0.00
0.01h
Eb.06
Accumulative running
time(day) threshold
0~9999
0
1Day
Eb.07
Accumulative running
time(hour) threshold
0.00~23.99
0.00
0.01h
Eb.08
Detection range of
frequency reached
0.0~100.0
0.2
0.1%
Eb.09
Any frequency reaching
detection value 1
0.00~b0.00
50.00
0.01Hz
Eb.10
Any frequency reaching
detection amplitude 1
0.0~100.0
0.0
0.1%