Revision History
The revision letter changes with related comments each time the document is updated.
Revision
Comment
A
Initial release of this document
Power Management
This Power Management System helps you to save energy by switching your monitor into a
low-power consumption mode when it has not been used for a certain period of time. Power
Management System operates with VESA DPMS compliant video card installed in your
Workstation.
Canvys highly recommends setting DPMS to activate after 15 minutes of non-usage in order
to optimize your displays lifetime and to avoid
Image retention damage
. We also recommend
users:
Not to leave the same image or viewing frame too long in one position.
Frequently changing and moving of image and viewing frame will help to avoid Image retention (also
called “Image Sticky”). Image retention is a phenomenon inherent to TFT LCD displays technology
itself, and as such, the occurrence of this “ghosting” effect is considered normal operation by the LCD
glass manufacturer. As a result, Canvys is not responsible for this damage and does not warrant any
displays against the occurrence of Image Sticking. We strongly advise that you follow the operating
recommendations listed above.
Power Management Modes
State
Normal
operation
DPMS Standby DPMS Suspend DPMS off
Horizontal Sync
Active
Inactive
Active
Inactive
Vertical Sync
Active
Active
Inactive
Inactive
Video
Active
Blanked
Blanked
Blanked
Power Indicator
LED ON
Green Flashing
(1sec interval)
Green Flashing
(1sec interval)
Green Flashing
(1sec interval)
Power
Consumption
250W Max
Less than 20W
Less than 20W
Less than 20W