background image

5

MODEL N0. 085-1562

LFT1224PST-A

IMPORTANT SAFETY INFORMATION AND PRECAUTION

   

I

   
   

    

    

     
    

     

    

    

    

    The  minimum  distance  between  the  brazier  and  the 

cylinder  is  30 in  /  76.2 cm,  which  prevents  the  hosepipe 
from  falling  between  the  cylinder  and  the  brazier. 
WARNING: The cylinder poses a risk of tripping.

nspect the hose assembly and burner prior to each use. 

If there is evidence of excessive abrasion or wear, or if 

the  hose  or  burner  is  damaged,  it  must  be  replaced by 
an appropriate part from the manufacturer.

   Open the door and inspect the gas connections prior to 
each use. Do not operate the unit if there is a gas leak. 
Have the appliance inspected annually by a qualified service person.  
  The pressure regulator and hose assembly provided with the appliance must be used. The replace-

ment part must be the same as the part specified by the manufacturer.
   For the assembly of LP-gas and leak checking, please refer to 

 

“Gas Connection” on page 8 and 

“Leak Test” on page 9.

   Children and adults should be alerted to the hazards of high surface temperatures and should stay 

away to avoid burns and prevent clothing ignition. 

Young children and pets should be carefully supervised when they are in the area of the appliance.

Any guard or other protective device removed for servicing the appliance must be replaced prior 

to operation. 

Clothing or other flammable materials should not be hung from the appliance or placed on or near 

the appliance.

   Do not use this appliance if any part has been under water. Immediately call a service technician to 
inspect the appliance and to replace any part of the control system which has been under water. 

    The LP-gas supply cylinder to be used must be constructed and marked in accordance with the specifi-

cations for LP-gas cylinders of the U.S. Department of Transportation (D.O.T.).

The cylinder supply system must be arranged for vapour withdrawal and the cylinder must include 

a collar to protect the cylinder valve. 

    Use only 20 lb / 9 kg LP-gas cylinders.

Do not burn wood or any other materials in this appliance.

The appliance must be isolated from the gas supply piping system by closing its individual manual 

shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or 
less than 1/2 PSI (3.5 kPa).

Other cylinders may be acceptable for use with the appliance, provided they are compatible with 

the appliance retention means and accompanied by illustration(s) depicting the cylinder mounted on 
the appliance using the cylinder retention means and the point of contact between the cylinder and 
the retention means.

Properly place the hose out of pathways where people may trip over it or 

in areas where they may be subject to accidental damage.

The burner must be replaced prior to the appliance being put into 

operation if it is clear that the burner is damaged. The replacement burner 
must be the same as the part specified by the manufacturer.

To clean the appliance including the burner, please refer to “Storage and

Maintenance” on page 10.

Содержание 085-1562

Страница 1: ...RANVILLE OUTDOOR FIRE TABLE MODEL N0 085 1562 LFT1224PST A ASSEMBLY INSTRUCTIONS Toll free 1 888 670 6684 IMPORTANT Please read this manual carefully before beginning assembly of this product Keep this manual for future reference ...

Страница 2: ...he installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable liquids and vapours in the vicinity of this or any other appliance An LP cylinder not connected for use must not be stored in the vicinity of this or any other appliance DANGER CARBON MONOXIDE HAZARD This appliance can produce carbo...

Страница 3: ...iew Parts List Installation Location Setup Gas Connection Operation Leak Test Lighting the Burners Storage and Maintenance Trouble Shooting Limited Warranty 3 4 4 5 6 7 9 9 10 9 10 11 8 7 8 8 IMPORTANT please take time to read these instructions thoroughly and follow each step carefully for safe and easy operation Retain for future reference and read carefully ...

Страница 4: ...Provided with a listed overfilling prevention device 3 Provided with a cylinder connection device compatible with the connection for the appliance Always place the appliance on a firm and level surface Solid fuels must not be burned in this gas appliance When using decorative Tempered glass use only Tempered glass INCLUDED The appliance must only be used outdoors in a well ventilated space and mus...

Страница 5: ...r near the appliance Do not use this appliance if any part has been under water Immediately call a service technician to inspect the appliance and to replace any part of the control system which has been under water The LP gas supply cylinder to be used must be constructed and marked in accordance with the specifi cations for LP gas cylinders of the U S Department of Transportation D O T The cylin...

Страница 6: ...6 EXPANDED VIEW ...

Страница 7: ...ase contact the Customer Service Centre 1 888 670 6684 The cover C as shown on the cover Cylinders are placed on the edge Note that the minimum distance is 30 in No Description Qty A B C D E 1 1 1 1 Outer ring pre assembled P22404A01144 Main body pre assembled P21125A01145 Lid P20709A01145 Cylinder ring P20803A01144 Tempered glass P99960A02003 Step 1 1 5 kg ...

Страница 8: ...TION Your gas appliance must be installed on a flat stable surface away from any combustible materials or construction Your gas appliance comes assembled ready for a gas connection 1 Remove the appliance from the box and place it on any level outdoor non combustible surface NOTE Do not place this appliance on grass or dirt These surfaces may prevent proper safety venting 2 Open the gas door and pu...

Страница 9: ...vice Centre for assistance 1 888 670 6684 5 If the connection does not leak continue to the next step 1 Make sure the control valve is OFF 2 Turn on the gas tank valve 3 Press and turn the control valve knob counterclockwise to LOW to light See the figure to the right 4 If the burner is lit continue pressing in the control valve knob for one minute to heat the thermocouple 5 When the turn the cont...

Страница 10: ... be kept clean If you disassemble the burner when cleaning the fire table please reassemble it according to the above right picture to make sure the burner induction tunnel is on and precisely covers the orifice base It is imperative that the control compartment burner and circulating air passageways of the fire table be kept clean It is recommended not to disassemble the burner Permanent installa...

Страница 11: ...ctions or subjected to abuse improperly treated neglected rusted by exposure to the elements misused and or if any repairs maintenance or service has been done by an unauthorized person Returns must be properly packaged and returned to the dealer from whom the product was acquired The manufacturer distributor and retailer will not be liable for any incidental or conse quential loss or damage arisi...