21
GB
•
• If the air conditioner is knocked over during use, turn off the unit and unplug it from the main
power supply immediately. Visually inspect the unit to ensure there is no damage. If you sus-
pect the unit has been damaged, contact a technician or customer service for assistance.
• In a thunderstorm, the power must be cut off to avoid damage to the machine due to light-
ning.
• To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed con-
trol device.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar co-
verings. Do not route cord under furniture or appliances. Arrange cord away from traffic
area and where it will not be tripped over.
• Do not open the unit during operation.
• When the air filter is to be removed, do not touch the metal parts of the unit.
• Hold the plug by the head of the power plug when taking it out.
ELECTRICAL INFORMATION
• The manufactures nameplate is located on the rear panel of the unit and contains electrical
and other technical data specific to this unit.
• Be sure the unit is properly grounded. To minimize shock and fire hazards, proper grounding
is important. The power cord is equipped with a three-prong grounding plug for protection
against shock hazards.
• Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you
intend to use is not adequately grounded or protected by a time delay fuse or circuit
breaker(the fuse or circuit breaker needed is determined by the maximum current of the unit.
The maximum current is indicated on the nameplate located on unit), have a qualified elec-
trician install the proper receptacle.
• Ensure the receptacle is accessible after the unit installation.
• Do not use extension cords or an adapter plugs with this unit.
However, if it is necessary
to use an extension cord, use an approved ”Dehumidifier” extension cord only (available at
most local hardware stores).
• To avoid the possibility of personal injury, always disconnect the power supply to the unit, be-
fore installing and/or servicing.
• All wiring must be performed strictly in accordance with the wiring diagram located on the
middle baffle of the unit (behind of the water bucket).
TAKE NOTE THE FUSE SPECIFICATIONS
• The unit’s circuit board(PCB) is designed with a fuse to provide overcurrent protection. The
specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V (or
350V), etc.
NOTE: All the pictures in the manual are for explanation purposes only. The actual shape of the
unit you purchased ma y be slightly different, but the op erations and functions are the same.
NOTE ABOUT FLUORINATED GASSES
• Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific
information on the type, the amount and the CO2 equivalent in tonnes of the fluorinated
greenhouse gas(on some models), please refer to the relevant label on the unit itself.
• Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
• Product uninstallation and recycling must be performed by a certified technician.