1.
Unscrew the cover from the packed valve on
the side of the outdoor unit. (See Fig. 5.9)
2. Remove protective caps from ends of valves.
3. Align flared pipe end with each valve, and
tighten the flare nut as tightly as possible by
hand.
4. Using a spanner, grip the body of the valve.
Do not grip the nut that seals the service
valve. (See Fig. 5.10)
5. While firmly gripping the body of the valve,
use a torque wrench to tighten the flare nut
according to the correct torque values.
6. Loosen the flaring nut slightly, then tighten
again.
7. Repeat Steps 3 to 6 for the remaining pipe.
INSTRUCTIONS FOR CONNECTING
PIPING TO OUTDOOR UNIT
REFRIGERANT PIPING CONNECTION
fig 5.9
fig 5.10
Torque from tightening the flare nut can snap off
other parts of valve.
Valve cove
USE SPANNER TO GRIP MAIN
BODY OF VALVE
62
© 2021, Elon Group AB. All rights reserved.
EN