L-L 265.00-BM 

7 / 24 

IMPORTANT 

Before using the space heater, carefully read all of the instructions and follow them scrupulously. The manufacturer cannot be 

held responsible for damage to persons and/or property caused by improper use of the equipment. 

This instruction manual is an integral part of the equipment and must therefore be stored carefully and passed on with the unit in 

the event of a change of ownership. 

 

1. DESCRIPTION 

Space heaters described in this manual, are designed for use in 

medium to large-sized rooms and buildings where a fixed or mobile 

heating system is required. 

The air required for combustion is sucked directly by the burner (6) 

installed on the heater, and can be supplied: 

•  from the outside by using the flexible connection tube (available 

as an accessory), which avoids consuming oxygen in the room to 

be heated, or  

•  from inside the room to be heated. In this case, the room must be 

well ventilated to guarantee sufficient exchange of air. 

The flow of hot air is moved by the high-efficiency fan (4): air is 

heated by the thermal energy generated during la combustion and 

heat from the smoke is transmitted to the fresh air through the 

metal walls of the sealed combustion chamber and the heat 

exchanger. After the combustion products are cooled, they are 

conveyed to a discharge duct and eliminated through a chimney or 

flue large enough to guarantee their removal. 

The space heaters can work with burners having ON-OFF work 

modes and fuelled by natural gas or propane. 

 

Warning 

Only burners approved by the manufacturer and listed in 

the “TECHNICAL SPECIFICATION TABLE” can be used.  

The heater’s certification and warranty will lapse if the 

burner is replaced with a non-original model, even if it has 

similar specifications. 

 

All of the space heaters are fit with an electronic device that 

controls the flame and with: 

• safety devices (safety thermostat with manual reset, flame 

control, air pressure switch) that trip in case of serious 

malfunctions and cause a safety stop. In this case the heater 

stops, button (d) lights with a steady red light (Stop Light) and the 

heater can resume operation only after the cause of the stop has 

been identified and eliminated; 

•  control devices (temperature controller to control temperature of 

air outflow, complete with hour counter, fan thermostat, burner 

thermostat, voltage control) that trip in case of minor operating 

faults or supply faults, causing temporary stop of the space 

heater. In this case, the heater will restart automatically when the 

required condition is restored. 

The section “TROUBLESHOOTING” describes all possible operating 

faults and their possible remedies. 

 

2. CONDITIONS OF SUPPLY 

The heater is delivered with parts to be assembled and set as 

described in chapter 4. 

• Heater body 

• Burner  

• Air distribution connector 

•  Any required accessories (flue pipes, air distribution pipes, etc.) 

 

Warning 

Prior to installation, burner adjustment and ignition, the 

space heater should be assembled in full.  

All assembly operations should only be performed by 

professionally qualified personnel only. 

The following are also supplied: 

•  use and maintenance manuals for 

• space heater 

• burner 

•  manuals with drawings and spare part lists: 

• space heater 

• burner 

 

Warning 

All documents provided constitute an integral part of the 

unit.  

The documents should therefore be looked after with care 

and supplied with the unit in the event of a change in 

ownership. 

 

Parts are to be transported and moved using either a manual or 

automatic forklift truck with sufficient load capacity. 

 

Warning 

Never try to lift the heater manually. Doing so could cause 

serious physical injury. 

 

 

3. GENERAL ADVICE 

The space heater must be installed, adjusted, and used in 

conformity to national and local laws and regulations for its 

operation. 

General guidelines: 

•  Follow the instructions in this booklet very carefully; 

•  The heater is not installed in an area where there is a high risk of 

fire or explosions; 

• Minimum clearances from combustible material must be: 

  1 m (3 feet) from side and rear (air inlet) of heater  
  1 m(3 feet) on top of heater 
  3 m (10 feet) on air outlet of heater. 

•  Keep inflammable material at a safe distance from the heater 

(minimum 3 metres); 

•  Check that there is no overheating of walls, ceilings or floors made 

of inflammable materials, 

•  All precautions have been taken to prevent fires; 

•  The room being heated must be sufficiently ventilated so that the 

heater has enough air to function properly; 

•  The heater must be near a chimney or chimney flue and an 

electrical panel conforming to declared specifications; 

•  Check the heater before switching it on and at regular intervals 

during its use; 

•  After use, make sure the disconnecting switch is off. 

When using any type of space heater it is obligatory: 

•  not to exceed the maximum heat output level of the furnace 

(“TECHNICAL SPECIFICATION TABLE”); 

•  make sure that the air flow is not below the rated level; check that 

there are no obstacles or obstructions to the air suction and/or 

delivery ducts, such as sheets or covers on the equipment, walls 

or large objects near the heater. 

 

 

 

 

Содержание JUMBO 400

Страница 1: ...L L 265 00 BM 1 24 INSTRUCTIONS MANUAL MANUEL D INSTRUCTIONS SPACE HEATER GENERATEUR D AIR CHAUD JUMBO 400 JUMBO 600 JUMBO 800 FR EN...

Страница 2: ...ING MATERIALS PAPER OR CARDBOARD AT SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PR...

Страница 3: ...t in gas leaks and fire or explosion from the leak The hose assembly must be protected from the traffic building materials and contact with hot surfaces both during use andwhile in storage WARNING Pro...

Страница 4: ...R REFROIDISSEMENT 4 COMBUSTION CHAMBER CHAMBRE DE COMBUSTION 5 BURNER BRULEUR 6 THERMOSTATS L2 BOX BOITIER THERMOSTATS L2 7 HOISTING BRACKETS TRIERS DE LEVAGE 8 SUPPORT HANDLE SUPPORT POIGNEE 9 WHEEL...

Страница 5: ...INTAKE FOR PRE HEAT FILTER PRISE POUR FILTRE PR CHAUFFAGE f CABLE CLAMP FOR POWER CABLE PRESSE C BLES POUR C BLE D ALIMENTATION g TEMPERATURE CONTROLLER THERMOR GULATEUR h BURNER LIGHT VOYANT BR LEUR...

Страница 6: ...f f c c d d d d d a a a e e e a GAS SELECTOR VALVE VALVE S LECTEUR GAZ b MANIFOLD PRESSURE PORT PORT PRESSION BRULEUR c MANIFOLD PRESSURE REGULATOR R GULATEUR PRESSION d MAIN GAS VALVE SOUPAPE PRINCIP...

Страница 7: ...stop of the space heater In this case the heater will restart automatically when the required condition is restored The section TROUBLESHOOTING describes all possible operating faults and their possib...

Страница 8: ...or ceiling must always be at least 1 metre 4 2 POWER CONNECTIONS Warning The 120V unit is fitted with a proper power cord The 220V equipment is fitted with a temporary power cable used for the final...

Страница 9: ...r check that the direction of rotation of the fan matches the direction shown on the fan itself The air distribution channels can be connected by using the various accessories supplied placing the con...

Страница 10: ...ter operation and not with the heater off The space heater has a gas ramp with gas filter pressure regulator safety electrovalve work electrovalve pressure stabilizer pressure valve It is good practic...

Страница 11: ...y to change the kind of gas from natural gas to L P G or viceversa follow the detailed instructions indicated in section CHANGING TYPE OF GAS Only when the heater has been prearranged according to the...

Страница 12: ...tests are completed the hole drilled for the probe must be sealed with a material that is resistant to high temperatures and that ensures the tube remains airtight 5 OPERATING INSTRUCTIONS 5 1 START...

Страница 13: ...y set to 35 C with hysteresis of 5 C Red LED OUT 1 shows the operating state of the fan thermostat LED ON the fan is on LED OFF the fan is off Control of trip temperature of burner thermostat The temp...

Страница 14: ...amaged wires or connectors if necessary 6 5 CHECKING AND TESTING THE BURNER To reach the burner Remove the burner fixing screw Remove the burner and follow the checking and cleaning instructions in th...

Страница 15: ...and recalibrate the burner Incorrect setting of burner Clean and recalibrate the burner The burner goes on and off alternately and LED OUT 2 on the temperature controller is OFF when the burner goes...

Страница 16: ...NTROL LAMP LAMPE TEMOIN SECURITE DE SURCHAUFFE L1 BURNER THERMOSTAT setting 90 C THERMOSTAT BRULEUR r gulation 90 C TA ROOM THERMOSTAT PLUG PRISE THERMOSTAT D AMBIACE RE2 DELAYED IGNITION RELAY RELAIS...

Страница 17: ...NTROL LAMP LAMPE TEMOIN SECURITE DE SURCHAUFFE L1 BURNER THERMOSTAT setting 90 C THERMOSTAT BRULEUR r gulation 90 C TA ROOM THERMOSTAT PLUG PRISE THERMOSTAT D AMBIACE RE2 DELAYED IGNITION RELAY RELAIS...

Страница 18: ...sea level U S A and Canada Heat input BTU h 393 052 Manifold pressure in w c 2 40 Burner head position N 4 Burner Air setting N 4 7 Fuel consumption CFH 158 40 Altitude 2 000 4 500 ft above sea level...

Страница 19: ...nd Canada Heat input BTU h 593 609 Manifold pressure in w c 1 60 Burner head position N 3 Burner Air setting N 3 4 Fuel consumption CFH 239 22 Altitude 2 000 4 500 ft above sea level Canada only Heat...

Страница 20: ...ut BTU h 805 499 Manifold pressure in w c 2 20 Burner head position N 5 Burner Air setting N 5 2 Fuel consumption CFH 317 16 Altitude 2 000 4 500 ft above sea level Canada only Heat input BTU h 724 95...

Страница 21: ...L L 265 00 BM 21 24 NOTICE DE MONTAGE DU PIED DE LA POIGNEE FOOT HANDLE ASSEMBLY INSTRUCTION...

Страница 22: ...L L 265 00 BM 22 24...

Страница 23: ...L L 265 00 BM 23 24...

Страница 24: ...L L 265 00 BM 24 24 BIEMMEDUE S p A Via Industria 12 12062 Cherasco CN Italy Tel 39 0172 486111 Fax 39 0172 488270 www biemmedue com bm2 biemmedue com...

Отзывы: