SmartLock
®
UltraLite Plus
Page 4 of 16
Installation Manual
Oct 2013 • Rev. 1.6
Specifications
Power Requirements
UltraLite Plus controller
........................................................................ 12 VDC, 40 mA
NOTE:
When determining power supply current requirements, add lock and reader current draw.
Onboard Output
Lock control relay
......................................................... form “C”, rated @ 30 VDC, 2 A
Onboard Inputs
Exit button
............................................................................................... normally open
Door contact
........................................................................................... normally closed
Reader Cable
Wiegand readers ..................................................
6 conductors (twisted pair not required)
..................................................................................
#22 AWG, overall shielded cable
..........................................................................................................
152 m [500'] max.
iButton
®
readers .................................................................................................
6 conductors
......................................................................
#22 AWG, shielded or unshielded cable
...............................................................................................................
15 m [50'] max.
Dimensions
UltraLite Plus controller
............................. 114.3 mm (h)
x
44.5 mm (w)
x
25.4 mm (d)
...........................................................................................
[4.5'' (h)
x
1.75'' (w)
x
1'' (d)]
Operating Temperature
.............................................. -35
o
C to 65
o
C [-31
o
F to 150
o
F]
Housing
................................................................................................... polycarbonate
Specifications subject to change without notice.
IMPORTANT:
In some jurisdictions the use of a UL-approved power supply
and connection to the fire alarm system for emergency release may be
required. Installers should contact the fire marshal office or local
authority having jurisdiction to verify the specific requirements. A building
permit may be required in some jurisdictions for the installation of maglocks.