Troubleshooting 

The SmartLock UltraLite Plus uses a series of ON/OFF tones (beeps) to indicate 
operational status to the user. These beeps can be used for troubleshooting.  
 

NOTE

: The UltraLite Plus controller emits two types of beeps: high (2,300 Hz) 

and low (675 Hz). 
 

Condition 

Time (ms = millisecond) 

Mode 

Power Up 

100 ms ON 

Single Beep 

Real-Time Clock 
Failure 

150 ms ON 
150 ms OFF 

Continuous 

Beeps 

Access Granted 

130 ms ON 

Single Beep 

Access Denied 

first beep

: 130 ms ON then 20 ms OFF 

second beep

: 130 ms ON then OFF 

Two Beeps 

Door-Held-Open 

Continuous tone 

Continuous 

Beep 

Programming 
Successful 

transfer start

: 1 s ON at 2,300 Hz (high beep).  

during transfer

: 500 ms ON and 500 ms OFF. 

transfer end

: 2 s ON at 675 Hz (low beep). 

Low Beep at 

End 

Programming 
Unsuccessful 

start

: 1 s ON at 2,300 Hz (high beep) 

error

: 130 ms ON and 20 ms OFF 

Four Beeps 

Data Transfer 

500 ms ON  
500 ms OFF  

Continuous 

Beeps 

 
 
® SmartLock is a registered trademark of Cansec Systems, Ltd. 
® iButton is a registered trademark of Maxim Integrated Products, Inc. 

 

 

Содержание SmartLock UltraLite Plus

Страница 1: ...SmartLock UltraLite Plus INSTALLATION MANUAL October 2015...

Страница 2: ...K RELAY WIRING 10 TROUBLESHOOTING 14 SMARTLOCK ULTRALITE PLUS COMPLIANCE STATEMENT 15 Copyright 2012 2015 Cansec Systems Ltd All rights reserved Connector Installation Note 6 Wiegand Reader 7 iButton...

Страница 3: ...uest to exit button and a door contact If a door contact input is connected the controller will automatically relock the door once it re closes In addition an audible alert can be generated on the rea...

Страница 4: ...m 500 max iButton readers 6 conductors 22 AWG shielded or unshielded cable 15 m 50 max Dimensions UltraLite Plus controller 114 3 mm h x 44 5 mm w x 25 4 mm d 4 5 h x 1 75 w x 1 d Operating Temperatu...

Страница 5: ...r contact input must be bypassed if not used To bypass connect a jumper wire between the door contact input and Ground 3 If the cable feed hole on the controller back box is too small drill a larger h...

Страница 6: ...nstallation Manual Oct 2013 Rev 1 6 Wiring CONNECTOR INSTALLATION NOTE IMPORTANT Wires face into the center of the PCB for installation into housing CONNECT WIRES ONTO THE PLUGGABLE CONNECTORS IN THIS...

Страница 7: ...Manual Oct 2013 Rev 1 6 WIEGAND READER IMPORTANT Before applying power to the controller verify that the reader is connected correctly as per the manufacturer s specifications 6 CONDUCTOR 20 AWG NON...

Страница 8: ...SmartLock UltraLite Plus Page 8 of 16 Installation Manual Oct 2013 Rev 1 6 IBUTTON READER 6 CONDUCTOR 22 AWG TWISTED OR NON TWISTED PAIR SHIELDED CABLE MAX DISTANCE IS 50 FT...

Страница 9: ...for forced entry and door held open annunciation The lock relay is deactivated when the door closes before the unlock time ends 3 If door contact is not used you must connect a jumper wire between the...

Страница 10: ...te Plus Page 10 of 16 Installation Manual Oct 2013 Rev 1 6 Lock Relay Wiring DC ELECTRIC STRIKES UP TO 250MA NOTE Use a 1N400x series diode at the lock device as shown to prevent back EMF from damagin...

Страница 11: ...Lite Plus Page 11 of 16 Installation Manual Oct 2013 Rev 1 6 DC ELECTRIC STRIKES MORE THAN 250MA NOTE Place a 1N400x series diode at the external relay coil as shown to prevent back EMF from damaging...

Страница 12: ...ck UltraLite Plus Page 12 of 16 Installation Manual Oct 2013 Rev 1 6 AC ELECTRIC STRIKES NOTE Place a 1N400x series diode at the external relay coil as shown to prevent back EMF from damaging the cont...

Страница 13: ...maging the controller IMPORTANT In some jurisdictions the use of a UL approved power supply and connection to the fire alarm system for emergency release may be required Installers should contact the...

Страница 14: ...s OFF Continuous Beeps Access Granted 130 ms ON Single Beep Access Denied first beep 130 ms ON then 20 ms OFF second beep 130 ms ON then OFF Two Beeps Door Held Open Continuous tone Continuous Beep Pr...

Страница 15: ...e is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning th...

Страница 16: ...rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Complies To European Community Compliance Statement This product has been tested and found to comp...

Отзывы: