Quick Start Guide 

April 2014 • Rev. 1.3 

Configure 

1.

 

Address Configuration

 - enter the IP address, subnet mask, default gateway, and 

port number provided by your network administrator. 

2.

 

Operational Mode

 - select your access control system.  

NOTE: I

dle auto-disconnect is enabled by default for SmartLock Pro/SMA, Zodiac Max 

and SmartLock Pro Plus with a value of 1. 

3.

 

Remote Diagnostics

 - select remote diagnostics and enter an optional 8-digit 

password. 

4.

 

RS485 Serial Interface – 

These settings are set accordingly when the operational 

mode is selected.  Maestro and SmartLock Pro/Connect share the same default 
settings. Zodiac Max also shares the same settings except the baud rate is set to 
38400. The default settings for Maestro and SmartLock Pro/Connect are as 
follow: 
Baud Rate: 9600 
Parity: None, 1 Stop Bit 
Data Bits: 8 Bits 

5.

 

IP Security is optional. Select the checkbox “Only allow connections from the IP 
below” and enter the IP address that is allowed to connect to this Canlan for 
communication. Leave the checkbox unchecked if IP Security is not used. 

6.

 

Click 

Save

 if any changes were made. 

7.

 

Optionally, click 

Backup

 to back up the configuration to a binary file for future 

restoration. The file will be saved in the same folder as the Canlan configuration 
software. 

Содержание Canlan M200

Страница 1: ...Cutting edge simplicity Canlan M200 QUICK START GUIDE April 2014 ...

Страница 2: ...ion software 3 Connect the Canlan M200 to your PC using the USB cable provided NOTE The cross over network cable provided may be used instead of the USB cable Refer to the Canlan M200 Installation Manual for important connection information 4 Verify the COM port number used by the Canlan M200 by going to Control Panel System Hardware Device Manager Port Example USB Serial Port COM4 5 From the Canl...

Страница 3: ...CanLan M200 Page 3 of 6 Quick Start Guide April 2014 Rev 1 3 6 Select Connect via Serial Port and choose the appropriate COM port from the drop down menu ...

Страница 4: ...M200 using the AC DC adaptor provided If the Canlan M200 is already powered on use a pin to press and release the reset button in the reset pin hole 8 Press OK within 20 seconds You should see the message Unit Online along with all default configuration parameters Device Reset Button ...

Страница 5: ...ine 1 Make sure you are using the right COM port number 2 Unplug the AC DC adaptor and plug it back in again or use a pin to press and release the reset button if it s already powered on 3 Wait for the Cfg Err LED to come on then click the Connect button to retry the connection 4 For more troubleshooting tips see the Canlan M200 Installation Manual ...

Страница 6: ...tional mode is selected Maestro and SmartLock Pro Connect share the same default settings Zodiac Max also shares the same settings except the baud rate is set to 38400 The default settings for Maestro and SmartLock Pro Connect are as follow Baud Rate 9600 Parity None 1 Stop Bit Data Bits 8 Bits 5 IP Security is optional Select the checkbox Only allow connections from the IP below and enter the IP ...

Отзывы: