Air

-485

®

 is a high performance 900MHz frequency-hopping spread spectrum (FHSS) long-range 

wireless modem. It provides a reliable wireless data link to RS-485 serial devices and offers a 
simple yet cost-effective alternative to running costly RS-485 data cables, especially in 
commercial environments that make wire connections challenging or impractical. 

Air

-485

®

 is 

optimized to work with Cansec’s SmartLock, Hurricane & Maestro, and Zodiac 

products but can also be used with most products that support 2-wire RS-485 communication. 
The wireless link that 

Air

-485

®

 modems provide is totally transparent to the connected devices. 

 

Features 

Plug and Play Communications 

Unlike most wireless modems, 

Air

-485

®

 does not require the use of a PC or the installation of 

complicated software to set up the radio and communication parameters. Instead, 

Air

-485

® 

modems are configured through simple DIP switch settings (see Figure 1 and 2 on the following 
pages). 

Long Range 

Indoor/Urban: up to 400 m (1,300 feet) depending on antenna height and RF interference. 

Outdoor line-of-sight: up to 10 Km (6 miles) with standard antenna provided. 

USB and RS-485 Support 

Air

-485

®

 modems support both USB and 2-wire RS-485 connections. When connected to the 

PC using USB, the device is powered from the USB. When connected to an RS-485 data cable, 
an external power supply must be used. 

Air

-485

®

 automatically detects the type of connection 

and configures itself automatically. Support for both types of connections provides greater 
flexibility in accommodating even the most complex configuration (examples provided later in 
this document.) 

Adjustable RF Power Level 

Four output power levels (10, 250, 500 and 1000 milliwatts) can be easily set in the field using 
two DIP switches. The RF power level should be set higher as needed for longer range. Note 
that setting the RF power to a high level when doing testing at very short range (under 2 m/6 
feet) can overload the receiver and cause erratic operation. 

Содержание AIR-485

Страница 1: ...AIR 485 INSTALLATION MANUAL November 2014...

Страница 2: ...age 2 of 14 Installation Manual November 2014 Rev 2 2 CA AIR485 Important Notice Do not operate the AIR 485 modem with the antenna removed This will cause irreparable damage which is not covered under...

Страница 3: ...e surface MOBILE OBSTRUCTIONS Do not locate AIR 485 units where their line of sight to the other unit s can be obstructed by trucks or other mobile equipment TECHNICAL SUPPORT Prior to calling Technic...

Страница 4: ...ems are configured through simple DIP switch settings see Figure 1 and 2 on the following pages Long Range Indoor Urban up to 400 m 1 300 feet depending on antenna height and RF interference Outdoor l...

Страница 5: ...sive tools and power meters Multiple Network Support Because the range of the Air 485 modems can be up to 10 Km 6 miles line of sight it is possible that installations in close proximity could interfe...

Страница 6: ...14 Installation Manual November 2014 Rev 2 2 Setup DIP Switch Settings There are two sets of DIP switches which must be set Figure 1 Front NOTE The RESET button must be pressed whenever a DIP switch s...

Страница 7: ...RS 485 bus as Master and set the field units as Slaves 5 Switches 2 and 3 The factory default setting is Low Power If the distance between the Master and Slave s is MORE THAN 100 feet set the switches...

Страница 8: ...and corresponding Slaves should all be on the same Network ID Setting the Network ID can be done using the DIP switches as shown in the diagram below 3 Signal Strength Signal Strength LEDs indicate th...

Страница 9: ...Outdoor Installation For outdoor applications use the CA AIR485 N which consists of an Air 485 modem and a plastic NEMA enclosure This configuration is temperature rated for 40o C to 85o C 40 F to 18...

Страница 10: ...AIR 485 Page 10 of 14 Installation Manual November 2014 Rev 2 2 Wiring Diagrams Wiring H1000 NOTE The EIA RS 485 standard does not permit T Tap or Star connections...

Страница 11: ...AIR 485 Page 11 of 14 Installation Manual November 2014 Rev 2 2 Wiring SmartLock NOTE The EIA RS 485 standard does not permit T Tap or Star connections...

Страница 12: ...AIR 485 Page 12 of 14 Installation Manual November 2014 Rev 2 2 Typical Air 485 Configuration for SmartLock Air 485 Without CLAUSB or CanLan Air 485 With CLAUSB CanLan on Remote Site...

Страница 13: ...Supports maximum 30 panels Supports maximum 16 Air 485 slaves No communications between Air 485 slaves No Air 485 repeaters Works with most 2 wire RS 485 products NOTE The supported baud rates are 48...

Страница 14: ...n Rate 115 2 Kbps Receiver Sensitivity 102 dBm 0 00001 BER 115 2 Kbps Transmission Output Power 10 250 500 and 1000 mW Power Requirement USB Power low RF output or 12VDC 1A high RF output Network Topo...