OM-1587 Page 33
SECTION 12 – SETTING SharpArc
E
CONTROL
12-1. Selecting And Adjusting SharpArc
E
Control
Ref. S-0259
1
Arc
SharpArc
is “Arc” on the display.
It is used to adjust arc cone width
and arc characteristics.
Use front panel parameter select
button to move > to select Arc. Use
Display Control to adjust Arc
setting.
SharpArc
setting range is from 0
to 20. The factory default is set at
zero (0). When Arc value is in-
creased toward 20, the arc cone
narrows and the weld puddle be-
comes less fluid.
5 0
T r i m
2 0 0
I P M
> P r g
1
0 3 5 “ S t
5 0
T r i m
2 0 0
I P M
P r g
1
> A r c
0
1
Parameter
Select
5 0
T r i m
2 0 0
I P M
P r g
1
> A r c 2 0