WX6000 / SX6000
User Commands
- 41 -
FLTWRN
Filter warning indication at startup
Format
FLTWRN=<Filter warning parameter: ID>
GET
□
FLTWRN / ?
△
FLTWRN
<Filter warning parameter: ID>
OFF Turned
off
ON Turned
on
Environment
Power
Input
OFF ON
PM
D-RGB A-RGB
COMP
HDMI
None
X O X
-
Response
"i:OK" is returned when setting of filter warning indication at startup was completed successfully.
For '
GET FLTWRN
' or '
?FLTWRN
', current setting of filter warning indication at startup is returned as
'g:FLTWRN=<Filter warning parameter: ID>'
For details on other responses, refer to the "Error List".
Description
(1) This command is used to set the indication of filter warning at startup.
(2) This command functions in the same way as when "Installation setting" - "On screen" -
"Filter warning indication" are selected on the menu.
(3) The current setting of filter warning indication at startup can be obtained using the GET
command. ("
GET FLTWRN
")
(4) The setting of Filter warning indication at startup retains the last setting after the power is
turned off.
Example
Setting
> FLTWRN=OFF
Filter warning indication at startup is disabled.
< i:OK
Reference
> GET FLTWRN or ?FLTWRN
The setting of filter warning indication at startup is acquired.
< g:FLTWRN
*Commands are indicated by ">", and responses are indicated by "<".