BT1-D005-A-ENG
©2022.04
CANON
INC.
7/20
Setting - <Setting> - <System> - Indicator
3.1 Setting the indicator on/off
System screen
I G : 5 0
<System>
Indicator:
Tally:
Cafs:
ON
ON
ON
I G : 5 0
<System>
Indicator:
Tally:
Cafs:
ON
ON
ON
to select
Selection item
(D)
ON
OFF
Function
Lighted
Extinguished
(D): Default value
Setting - <Setting> - <System>
3. Accessing the System screen
Setting screen
I G : 5 0
<Setting>
I-Gain:
RBF:
System
50
000
× 3
I G : 5 0
<Setting>
RBF:
System
000
AF:
System screen
I G : 5 0
<System>
Indicator:
Tally:
Cafs:
ON
ON
ON
Setting - <Setting> - RBF
2. Setting remote back focus
(RBF models only)
Adjusts the flange back position.
Setting screen
I G : 5 0
<Setting>
I-Gain:
RBF:
System
50
000
× 2
I G : 5 0
<Setting>
I-Gain:
RBF:
System
50
000
to adjust
Selection item
000
–
999
Function
000 end: Positive end of flange back knob
999 end: Negative end of flange back knob
Default value: Set at the factory before shipment.