Introduction

The following rules apply throughout this Service Manual:

1. Each chapter contains sections explaining the purpose of specific functions and the relationship between electrical and mechanical systems with refer-

ence to the timing of operation.
In the diagrams,

 represents the path of mechanical drive; where a signal name accompanies the symbol , the arrow

 indicates the

direction of the electric signal.

The expression "turn on the power" means flipping on the power switch, closing the front door, and closing the delivery unit door, which results in

supplying the machine with power.

2. In the digital circuits, '1'is used to indicate that the voltage level of a given signal is "High", while '0' is used to indicate "Low".(The voltage value, how-

ever, differs from circuit to circuit.) In addition, the asterisk (*) as in "DRMD*" indicates that the DRMD signal goes on when '0'.

In practically all cases, the internal mechanisms of a microprocessor cannot be checked in the field. Therefore, the operations of the microprocessors

used in the machines are not discussed: they are explained in terms of from sensors to the input of the DC controller PCB and from the output of the

DC controller PCB to the loads.

The descriptions in this Service Manual are subject to change without notice for product improvement or other purposes, and major changes will be com-

municated in the form of Service Information bulletins.

All service persons are expected to have a good understanding of the contents of this Service Manual and all relevant Service Information bulletins and be

able to identify and isolate faults in the machine."

Содержание Super G3 FAX Board-T1

Страница 1: ...Sep 14 2005 Portable Manual FAX Board Super G3 FAX Board T1...

Страница 2: ......

Страница 3: ...need arises In the event of major changes in the contents of this manual over a long or short period Canon will issue a new edition of this manual The following paragraph does not apply to any countri...

Страница 4: ...uiring care to avoid combustion fire Indicates an item prohibiting disassembly to avoid electric shocks or problems Indicates an item requiring disconnection of the power plug from the electric outlet...

Страница 5: ...ed to indicate Low The voltage value how ever differs from circuit to circuit In addition the asterisk as in DRMD indicates that the DRMD signal goes on when 0 In practically all cases the internal me...

Страница 6: ......

Страница 7: ...Error Code 1 1 1 1User Error Code 1 1 2 Service Error Code 1 1 2 1Service Error Code 1 Chapter 2 System Construction 2 1 Basic Construction 3 2 1 1Overview 3 2 1 2Modem PCB 3 2 1 3NCU PCB 4 2 2 Produc...

Страница 8: ......

Страница 9: ...program out of control has occurred 0232 Tx encoding error has occurred 0237 Rx decoding error has occurred 0261 Tx Rx system error has occurred 0280 Tx at time of transmission the procedural signal h...

Страница 10: ...of ECM transmission the procedural signal has been transmitted more than specified after transmission of PPS EOP 0770 Tx at time of ECM transmission no meaningful signal is received after transmission...

Страница 11: ...such as those in NCU or speaker SDRAM It is used as the memory for encoding decoding of image data during transmitting receiving and that for MPU work area In addition it is used for storing the trans...

Страница 12: ...l ITU T V 27ter 2 4Kbps 4 8Kbps ITU T V 29 7 2Kbps 9 6Kbps ITU T V 17 TC 7 2Kbps TC 9 6Kbps 12Kbps 14 4Kbps ITU T V 34 2 4Kbps 4 8Kbps 7 2Kbps 9 6Kbps 12Kbps 14 4Kbps 16 8Kbps 19 2Kbps 21 6Kbps 24Kbps...

Страница 13: ...tion no Answering machine connection no Fax Tel switching no Divided Transmission yes Remote reception no Polling F code no Memory box no Password reception no Machine telephone No transmission yes Us...

Страница 14: ......

Страница 15: ...Sep 14 2005...

Страница 16: ......

Отзывы: