User Command Specifications
9. Details of command BRI
1
BRI
BRI
BRI=<Brightness setting: Number>
Brightness setting (-20 to 20)
This sets the screen brightness.
-1
A "busy" response is given while the zoom or focus lens is being driven.
-2
Menu
[Image adjustments] - [Brightness]
[Image adjustments] - [Brightness]
-3
-4
Setting
> BRI=-10
This sets the brightness to -10.
< i:OK
Reference
> GET BRI or ?BRI
This retrieves the brightness.
< g:BRI=-10
Obtain settable parameter range (Min, Max)
> RANGE BRI
< r:BRI=N, -20, 20
Any value from -20 to 20 can be set for the brightness.
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command States
OFF ON
PM
×
○
×
×
○
×
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
This command is the same as the menu functions in the table below.
The currently selected input signal and image mode are used for these settings.
The current brightness can be acquired using the applicable GET command.
SX50
SX6
SX60
SX6
Example
Brightness setting
The RANGE command can be used to obtain the parameter range that can be set at
that time.
It can be executed when the projector is in both the
remote mode
and
power-on
status at the
same time.
"i:OK" is returned if the parameter was set properly.
Model
Number
X600
Commands
Function
Parameter
Description
Response
Format
SX50
01.00**
01.01**
01.01**
X600
○
SX60
01.01**
Model
Power
Input
D-RGB A-RGB1 A-RGB2 Comp
Video S-Video D-Video
Mode
Remote Local
Remarks
SCART
None
SX50
○
○
○
○
○
○
–
–
○
○
×
SX6
○
○
○
○
○
×
○
○
○
○
SX60
X600
○
Mode Control Setting Reference
Commands
supported
For details, refer to the RANGE command.
For all other responses, refer to "Error List."
(Refer to the ZCONTDRV command and FCONTDRV command.)
For details, refer to the GET command.
○
○
○