![Canon RE-350 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/canon/re-350/re-350_control-interface-commands-manual_61032022.webp)
22
2.4 Event Data Packet Table
Request OFF Line
$20
$8*
$00
$01
$00
Request ON Line
$20
$8*
$00
$00
$00
Request ON line
When the {
RS-232
} button on the front panel is pushed and the
RTS
signal line from the
PC
is on, the
RE-350
will
send this “Event Data Packet” to the
PC
. If the
RE-350
can receive the <Accepted> of the “E-response Packet” in 1
second, the
RE-350
’s mode will switch to [O
N
-L
INE
]. If not or no E-response after repeating the above “Event data
packet” twice, the
RE-350
will stay in [O
FF
-L
INE
] mode.
Request OFF line
When the {
RS-232
} button on the front panel is pushed to try to set the
RE-350
to [O
FF
-L
INE
] Mode and the
RTS
signal line from the
PC
is on, the
RE-350
will send this “Event Data Packet” to the
PC
. If the
RE-350
can receive the
<Accepted> of the “E-response packet”, the
RE-350
’s mode will shift to the [O
FF
-L
INE
] Mode. Also, if there is no
response from the
PC
, then the
RE-350
's mode changes to [O
FF
-L
INE
].
Event Description 1 byte 2 byte 3 byte 4 byte 5 byte
Header ID # EVENT# Para(H) Para(L)