Chapter 3 Troubleshooting
3-3
Troubleshooting by DIAG
For details including how to start the DIAG program, please see page 3-10.
ROM Check
Correct?
To Start of
Troubleshooting.
Correct?
Yes
No
Yes
No
Start of DIGA program
Font SIMM Check
Correct?
Yes
No
Replace the Font SIMM, and restart the
machine in DIAG mode.
The DIAG program will proceed.
Correct?
Yes
No
DRAM SIMM Check
Correct?
Yes
No
Replace the DRAM SIMM, and restart the
machine in DIAG mode
The DIAG program will proceed.
Correct?
Yes
No
EEPROM Check
Correct?
Yes
No
Replace the EEPROM, and restart the
machine in DIAG mode.
The DIAG program will proceed.
C
Replace the Main
Board. *1
* JP model only(Japanese font SIMM).
*1: Be sure to use the EEPROM from the original Main Board on the replaced new Main Board. (See page 1-5 for details.)
Содержание PS-7000
Страница 11: ...Chapter 2 Product Overview 1 Product Composition 2 1 2 Main Unit 2 4 3 Specifications 2 7 4 Upgrade Kit 2 9 ...
Страница 23: ...Chapter 3 Troubleshooting 1 Troubleshooting 3 1 2 LED Indication 3 9 3 DIAG Program 3 10 4 Test Print 3 12 ...
Страница 37: ...Chapter 4 Disassembly Assembly 1 Disassembly 4 1 2 Assembly 4 12 3 About HDD Format 4 13 ...
Страница 38: ...Chapter 4 Disassembly Assembly 4 1 1 Disassembly 1 1 External appearance ...
Страница 51: ...Chapter 5 Operation Principles 1 RIP 5 1 2 Color Control 5 2 3 Miscellaneous 5 5 4 System Configuration 5 7 ...
Страница 63: ...Chapter 6 Parts Catalog 6 PARTS LAYOUT PARTS LIST 6 1 ...
Страница 64: ...Chapter 6 Parts Catalog 6 1 6 PARTS LAYOUT PARTS LIST 1 EXTERNAL COVERS 2 MAIN FRAME ...
Страница 65: ...Chapter 6 Parts Catalog 6 2 3 LED PANEL BOARD 4 INTERNAL COMPONENTS ...
Страница 66: ...Chapter 6 Parts Catalog 6 3 5 POWER SUPPLY UNIT 6 OTHER ...