2) Operation panel / Easy-Scroll Wheel
1 drop = 9 to 18 mg
(4) Ink absorber counter setting
Before replacement of the logic board, check the ink absorber counter value, and register it to the replaced new logic board. (The value
can be set in 10% increments.)
In addition, according to the ink absorber counter value, replace the ink absorber (ink absorber kit). When the ink absorber is replaced,
reset the applicable ink absorber counter (to 0%).
- How to check the ink absorber counter value:
See
3-4. Verification Items, (1) Service test print
.
- How to set the ink absorber counter:
See
3-3. Adjustment / Settings, (6) Service mode, "Ink absorber counter setting."
No
Part name
Where to apply grease / oil
Drawing
No.
Grease / oil
Grease /
oil
amount
(mg)
Number of
drops x
locations
15
Easy-Scroll Wheel
base
Easy-Scroll Wheel sliding portions
(15)
Floil KG107A
9 to 18
1 x 4
16 Easy-Scroll Wheel
Joint of the ring keys (up / down /
right / left cursor buttons)
(16)
Floil KG107A
1 to 3
0.16 x 1
<3-3. Adjustment / Settings, (1) to (4)>