Malfunction
Copier B/W | imagePRESS 1135/1125/1110 Series |
The spread glue amount is unstable due to conducting
inappropriate procedure to adjust the glue amount(Perfect
Binder_A1 / Perfect Binder_C1)
[Symptom]
State of glue application to output products (book) is unstable even if spreading amount of glue has been adjusted.
[Cause]
It was reported in field that the spread amount of glue was unstable even after adjusting the spread amount of glue of Perfect
Binder. Check of the setting of glue amount adjustment in field revealed that glue amount adjustment was not performed properly
due to the following causes:
- Adjustment was performed wrongly
- Lack of explanation on the interaction between the service mode and the user mode both involved with adjusting the glue amount
in technical materials.
Here is the detailed explanation to the above:
<Adjusting work is performed wrongly>
A) Service Mode> SORTER> Adjust> GLUING is adjusted
This service mode is specified as unused in imagePRESS 1135 service manual. However this service mode might be adjusted
in field. The parameter of this service mode is adjusted as a reference position of the gap between stack of sheets (Signature)
and the glue spreading roller at the time of being shipped from factory, and so this setting should not be changed in field. Do not
change the parameter of the service mode otherwise the gap between stack of sheets (Signature) and the glue spreading roller
becomes too close or they might contact each other.
Caution:
Never adjust the below screws in the filed
- The screws firmly fixed with adhesive on the front side if the device - 1
Remove the lower internal cover and comfirm the screws [1] / [2] shown in the photo below:
- The screws firmly fixed with adhesive on the front side of the device - 2
Remove the upper internal cover and confirm the screws [3] shown in the photo below:
15
Содержание Perfect Binder B1
Страница 1: ...Troubleshooting Guide Perfect Binder A1 B1 C1 D1 E1 July 16 2019 Canon U S A Inc ...
Страница 98: ...2 15 Remove the frame 1 2 screws 2 16 Remove the Stack buffer tray motor unit 2 screws 1 connector 96 ...
Страница 103: ...2 24 Remove the e ring 1 CAUTION Do not misplace the e ring 1 2 25 Remove the Tray guide unit from the link 1 101 ...
Страница 123: ... CAUTION Match the notches on the Sensor mount to the plate guides to mount it 2 15 Remove the frame 1 2 screws 121 ...
Страница 229: ...9 Reverse the trimming assembly 10 Remove the 2 screws 1 and remove the sheet metal part 2 227 ...
Страница 244: ...9 Reverse the trimming assembly 10 Remove the 2 screws 1 and remove the sheet metal part 2 242 ...