- 16 screws
[CAUTION] Some screws are hidden behind the levers. Remove the screws holding the levers.
2-8) Remove the fixing bracket of the trimming assembly.
- 2 screws
2-9) Remove the screws fixing the Trimming assembly.
- 4 screws
[CAUTION]: Be sure to confirm that the Trimming blade is evacuated to a safe position before pulling it out. If the Trimming blade
is not evacuated to a safe position, evacuate the Trimming blade to a safe position following to the service manual.