Operational Checks to be Performed by the Service Engineer
The combination of DIP switch indications and service LED (LED201) lighting makes
it possible check the operational condition of the unit.
1.
Normal operation
During normal operation the DIP switches are in the following state: SW201-1: OFF,
SW201-2: OFF, SW201-3: OFF, SW201-4: OFF.
The service LED repeats a cycle consisting of 0.5 sec on and 0.3 sec off when the
unit is operating normally. When an error occurs, the service LED flashes in the cycle
shown below: header (1.0 sec on, 0.2 sec off), detected error details (0.3 sec on, 0.2 sec
off) and pause (2.0 sec off).
Figure 5-102
Use the information in Table 5-101 to identify errors based on service LED lighting
status. For example, when the service LED flashes twice in the header section, and three
times in the error detection section, a jam sensor delay jam has occurred.
5-2
COPYRIGHT © 1999 CANON INC.
CANON 2
×
500 SHEET PAPER DECK-C1 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 5 TROUBLESHOOTING
ON
OFF
• Normal operation
0.5
0.3
Header (variable)
Error detection details
(variable)
Pause (fixed)
Header
(variable)
1.0
0.2
0.3
0.2
2.0
1 cycle
ON
OFF
• Error detected
(Unit: sec)
(Unit: sec)
Содержание PAPER DECK-C1
Страница 4: ......
Страница 8: ......
Страница 12: ......
Страница 14: ......
Страница 36: ......
Страница 38: ......
Страница 56: ......
Страница 60: ......
Страница 78: ......
Страница 80: ......
Страница 84: ......
Страница 86: ......
Страница 88: ...PRINTED IN JAPAN IMPRIME AU JAPON 0299AB1 51 1 This publication is printed on 70 reprocessed paper ...