I. STANDARDS AND ADJUSTMENTS
A.
Overview
When a breakdown or jam occurs in the unit, the condition of the unit can be checked
by the user LED (LED1: green and orange 2-color light) on the LED PCB and the service
LED (LED201: red light) in the paper deck driver PCB. In combination with the DIP switch-
es (SW201) on the paper deck driver PCB you can check the details of breakdowns and
errors.
[1] User LED
[2] Service LED
[3] DIP switch
Figure 5-101
B.
Operational Checks to be Performed by the User
The condition of the user LED (LED1) in the unit enables you to check operational
conditions.
1) Continuous green light: the unit and the printer assembly are communicating nor-
mally.
2) Flashing orange light: a paper jam has occurred, a door is open or other condition
requiring operator intervention has occurred.
3) Continuous orange light: breakdown
The user LEDs operate only when the DIP switches are in the following state: SW201-
1: OFF, SW201-2: OFF, SW201-3: OFF, SW201-4: OFF (factory default settings).
5-1
COPYRIGHT © 1999 CANON INC.
CANON 2
×
500 SHEET PAPER DECK-C1 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)