AE Auto Adjustment [4] No. 402
In AE auto adjustment, adjustments are made so that the intensity of the lamp in AE
mode matches the AE sensor output of manual copy density 5 in reference to copies of
an original (Test Sheet) on the copyboard glass.
Making Adjustments
1) Place the Test sheet (NA-3) on the Copyboard, and close the copyboard cover.
2) Start [4] in service mode, and select No. 402 using the keypad.
•
The indicator indicates ‘402’.
3) Press the OK key.
•
The scanning lamp turns on, and the scanner moves to the AE position.
•
AE scanning is executed, and the intensity for AE scanning is automatically set.
•
Thereafter, the scanner returns to home position, and the scanning lamp turns off.
4) Press the Reset key.
•
Mode selection mode starts, indicating [4].
•
If necessary, execute No. 304.
Table 2-2
CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-9
Item
402
Function
AE scanning
intensity
automatic
adjustment
Description
Remarks
Automatic adjustment
occurs so that the
original is copied at copy
density 5 when ‘402’ is
executed.
Note:
If AE adjustment
fails, the density
indicator LED on
the control panel
F5 and F9 flash.
If such occurs,
make the adjust-
ment once again.
Lighter
Copy
density 5
Darker
Test Chart
Original
density