COPIER > ADJUST > VIFADJ
Item
Description
Details
To adjust the setting value of C-color primary transfer bias.
Use case
When an image failure occurs
Adj/set/operate method
Enter the setting value (switch negative / positive by * key) and press Apply key.
Display/adj/set range
-5 to 5
Default value
0
Related service mode
COPIER > ADJUS T > VIFADJ > TR1-HV-Y
COPIER > ADJUS T > VIFADJ > TR1-HV-M
COPIER > ADJUS T > VIFADJ > TR1-HV-K
TR1-HV-K
Title
Adjustment of primary transfer bias setting value (Bk)
Details
To adjust the setting value of Bk-color primary transfer bias.
Use case
When an image failure occurs
Adj/set/operate method
Enter the setting value (switch negative / positive by * key) and press Apply key.
Display/adj/set range
-5 to 5
Default value
0
Related service mode
COPIER > ADJUST > VIFADJ > TR1-HV-Y
COPIER > ADJUST > VIFADJ > TR1-HV-M
COPIER > ADJUST > VIFADJ > TR1-HV-C
TR2SF-HV
Title
Adjustment of secondary transfer bias setting value (front side)
Details
To adjust the setting value of secondary transfer bias (front side).
Use case
When an image failure occurs
Adj/set/operate method
Enter the setting value (switch negative / positive by * key) and press Apply key.
Display/adj/set range
-5 to 5
Default value
0
Related service mode
COPIER > ADJUST > VIFADJ > TR2BK-HV
TR2BK-HV
Title
Adjustment of secondary transfer bias setting value (back side)
Details
To adjust the setting value of secondary transfer bias (back side).
Use case
When an image failure occurs
Adj/set/operate method
Enter the setting value (switch negative / positive by * key) and press Apply key.
Display/adj/set range
-5 to 5
Default value
0
Related service mode
COPIER > ADJUST > VIFADJ > TR2SF-HV
ICL-HV
Title
Adjustment of bias setting value for ITB cleaning
Details
To adjust the bias setting value to be used for ITB cleaning.
Use case
When an image failure occurs
Adj/set/operate method
Enter the setting value (switch negative / positive by * key) and press Apply key.
Display/adj/set range
-5 to 5
Default value
0
FU-TMP
Title
Adjustment of setting value of Fixing Roller surface temperature
Details
To adjust the setting value of the surface temperature of the Fixing Roller.
Use case
When an image failure occurs
Adj/set/operate method
Enter the setting value (switch negative / positive by * key) and press Apply key.
Display/adj/set range
-2 to 2
Default value
0
8. Service Mode
272
Содержание MF720 Series
Страница 1: ...Revision 2 0 MF720 Series Service Manual...
Страница 12: ...Product Overview 1 Product Lineups 5 Product Features 7 Specifications 8 Name of Parts 14...
Страница 33: ...How to release Jam Remove the jammed paper and open close the ADF upper cover 2 Technical Explanation 25...
Страница 79: ...4 Click Import Export Import 1 2 2 Technical Explanation 71...
Страница 101: ...Periodical Service 3 Periodically Replaced Parts 94 Durable Parts 95 Periodical Services 96 Cleaning 97...
Страница 102: ...Periodically Replaced Parts No periodically replaced parts is set for this product 3 Periodical Service 94...
Страница 103: ...Durable Parts No durable parts is set for this product 3 Periodical Service 95...
Страница 104: ...Periodical Services No periodical service is set for this product 3 Periodical Service 96...
Страница 232: ...Adjustment 5 Overview 225 Adjustment at Parts Replacement 226...
Страница 248: ...Troubleshooting 6 Test Print 241 Trouble shooting items 243 Version Upgrade 244 Debug Log 248...
Страница 258: ...Error Jam Alarm 7 Outline 251 Error Codes 252 Jam Code 257...
Страница 267: ...Service Mode 8 Overview 260 COPIER 264 FEEDER 300 FAX 302 TESTMODE 308...
Страница 322: ...APPENDICES Service Tools 315 General Circuit Diagram 316 Print Sequence 317 Backup Data 318...