LV-8320 Basic Serial Command Specifications
-8-
6.4. Operation Requirements
When the projector’s status is any of below, Functional Execution Commands are limited.
Projector Status
Available Functional Execution Commands
In Standby
C00
:
POWER ON
Countdown in process
C00
:
POWER ON
→
Countdown is terminated
C01
:
POWER OFF
C02
:
POWER OFF
→
Countdown is terminated
Cooling Down in process
NONE (No Execution)
Cooling Down due to Abnormal
Temperature
NONE (No Execution)
Abnormal Temperature Status
NONE (No Execution)
Abnormal Power Status
NONE (No Execution)
Power Save / Cooling Down in process
NONE (No Execution)
Power Save Status
C00
:
POWER ON
C01
:
POWER OFF
Auto input
:
On1/On2 setting
Although transmit Input source commands, Auto
input does not operate.
Note) When the status is as above, even if the projector receives other commands,
it returns
[ACK] [CR].