LV-7290 / LV-7295 / LV-7390/ LV-8225 Expand Serial Command Functional Specifications
69
9.11.24 CR_FANCONTROL Command
Command “CR_FANCONTROL”[CR]
Details
Get selected Fan control setting status
Response
Acceptable “000_%a”[CR]
%a
“OFF” ----------------------- Fan control is OFF
“ON1” ----------------------- Fan control is ON1
“ON2” ----------------------- Fan control is ON2
Unacceptable “Error Code” [CR]
9.11.25 CR_DELAYCTRL Command
Command “CR_DELAYCTRL”[CR]
Details
Get setting status of Video delay control
Response
Acceptable “000_%1”[CR]
%1
“ON” ----------------------- Video delay control is active
“OFF” ---------------------- Video delay control is inactive
Unacceptable
“Error
Code”[CR]
9.11.26 CR_FILH Command
Command “CR_FILH”[CR]
Details
Get Filter used time
Response
Acceptable “000_%1”[CR]
%1
“00000”~”99999” ------------------- 0 hour to 99999 hours
Unacceptable
“Error
Code”[CR]
9.11.27 CR_FILREPL Command
Command “CR_FILREPL”[CR]
Details
Get the information of Filter replacement time
Response
Acceptable “000_%1”[CR]
%1
“1Y” ------------------- Over filter replacement time
“1N” ------------------ Within filter replacement time
Unacceptable
“Error
Code”[CR]
9.11.28 CR_FILTIMER Command
Command “CR_FILTIMER”
[CR]
Details
Get setting time which filter warning OSD is displayed
Response
Acceptable “000_%1”[CR]
%1
“2000” ----------------- 2000 hours
“3000” ----------------- 3000 hours
“4000” ----------------- 4000 hours
“OFF” ---------------- No OSD display
Unacceptable
“Error
Code”[CR]