![Canon LBP5050 Series Скачать руководство пользователя страница 85](http://html.mh-extra.com/html/canon/lbp5050-series/lbp5050-series_service-manual_2553253085.webp)
Chapter 5
5-5
0000
Description: Abnormal output from toner remaining detection sensor
(Yellow)
Cause: Memory controller PCB defect, DC controller PCB defect, toner
cartridge defect
- Check the connector of the DC controller PCB.
- Replace toner cartridge
- Replace DC controller PCB
0001
Description: Abnormal output from toner remaining detection sensor
(Magenta)
Cause: Memory controller PCB defect, DC controller PCB defect, toner
cartridge defect
0002
Description: Abnormal output from toner remaining detection sensor
(Cyan)
Cause: Memory controller PCB defect, DC controller PCB defect, toner
cartridge defect
0003
Description: Abnormal output from toner remaining detection sensor
(Black)
Cause: Memory controller PCB defect, DC controller PCB defect, toner
cartridge defect
E066
Environment sensor abnormality
Description: Environment sensor abnormality
Cause: Environment sensor defect, DC controller PCB defect
- Check the connector of the environment sensor, DC controller PCB.
- Replace environment sensor
- Replace DC controller PCB
E100
ITB/TOP sensor failed
Description: ITB/TOP sensor failed.
Cause: ITB/TOP sensor defect, DC controller PCB defect
- Check the connector of the ITB unit, DC controller PCB.
- Replace ITB unit
- Replace DC controller PCB
E100
Scanner unit, laser unit, BD abnormality
0000
Description: Yellow optical assembly failure.
Cause: Laser scanner defect, DC controller PCB defect
- Check the connector of the laser scanner unit, DC controller PCB.
- Replace laser scanner unit
- Replace DC controller PCB
0001
Description: Magenta optical assembly failure.
Cause: Laser scanner defect, DC controller PCB defect
0002
Description: Cyan optical assembly failure.
Cause: Laser scanner defect, DC controller PCB defect
0003
Description: Black optical assembly failure.
Cause: Laser scanner defect, DC controller PCB defect
E110
BD correction control failure
Description: The machine does not change to the scanner ready status, after
starting BD control.
Cause: Laser scanner unit defect, DC controller PCB defect
- Replace the laser scanner unit
- Replace DC controller PCB
E196
DCON ROM abnormality
DC controller PCB ROM update failed.
- Replace DC controller PCB
E197
Engine communication error
0000
Internal communication error
- Replace DC controller PCB
- Replace main controller PCB
E198
DC controller memory failure
Description: DC controller memory failure.
Cause: DC controller PCB defect
- Replace DC controller PCB
E747
EEPROM error
Code
Detection details
Treatment
Содержание LBP5050 Series
Страница 1: ...Aug 13 2008 Service Manual LBP5050 Series ...
Страница 2: ......
Страница 6: ......
Страница 11: ...Chapter 1 PRODUCT DESCRIPTION ...
Страница 12: ......
Страница 14: ......
Страница 22: ......
Страница 23: ...Chapter 2 TECHNICAL REFERENCE ...
Страница 24: ......
Страница 45: ...Chapter 3 DISASSEMBLY AND ASSEMBLY ...
Страница 46: ......
Страница 70: ...Chapter 3 3 22 F 3 92 2 Remove the fixing motor 1 1 connector 2 2 screws 3 F 3 93 1 2 1 2 3 3 ...
Страница 71: ...Chapter 4 MAINTENANCE AND INSPECTION ...
Страница 72: ......
Страница 74: ......
Страница 77: ...Chapter 5 TROUBLESHOOTING ...
Страница 78: ......
Страница 80: ......
Страница 90: ...Chapter 5 5 10 F 5 11 F 5 12 ...
Страница 91: ...Chapter 5 5 11 F 5 13 F 5 14 ...
Страница 93: ...Chapter 5 5 13 00 Cyan 01 Magenta 02 Yellow 03 black F 5 17 ...
Страница 94: ......
Страница 95: ...Chapter 6 APPENDIX ...
Страница 96: ......
Страница 98: ......
Страница 102: ......
Страница 103: ...Aug 13 2008 ...
Страница 104: ......