5
5
5-2
5-2
Adjustment > Outline > Main adjustment > Adjustment item
Adjustment > Outline > Main adjustment > Adjustment item
Outline
Main adjustment
This machine can perform the following adjustment and function setting.
Service mode or both of DIP Switch can carry out adjustment / setting.
CAUTION:
The setting range / setting unit of the service mode and DIP switch shares it.
Because a set value is memorized in Finisher Controller PCB, regardless of a host machine or the setting from a finisher, finally input numerical value becomes effective.
■
Adjustment item
Item
Bit setting of DSW1 in the finisher
controller PCB
Service mode
Range
Unit
Default
Reference
Adjusting the Stacker Alignment Position (A4)
ON
1 2 3 4 5 6 7 8
(LV.1)
SORTER > ADJUST > STALG1
-10 to 10 0.42 mm
0
" Adjusting the Stacker Alignment
Adjusting the Front Staple Position 5deg (A4)
ON
1 2 3 4 5 6 7 8
(LV.1)
SORTER > ADJUST > STP-F1
-6 to 6
0.49 mm
0
" Adjusting the Staple Position"(page 5-7).
Adjusting the Front Staple Position Less Than 45deg
(A4R)
ON
1 2 3 4 5 6 7 8
(LV.1)
SORTER > ADJUST > STP-F2
-6 to 6
0.49 mm
0
" Adjusting the Staple Position"(page 5-7).
Adjusting the Rear Staple Position 45deg (A4)
ON
1 2 3 4 5 6 7 8
(LV.1)
SORTER > ADJUST > STP-R1
-6 to 6
0.49 mm
0
" Adjusting the Staple Position"(page 5-7).
Adjusting the Rear Staple Position Less Than 45deg
(A4R)
ON
1 2 3 4 5 6 7 8
(LV.1)
SORTER
> ADJUST > STP-R2
-6 to 6
0.49 mm
0
Содержание J1
Страница 4: ...Blank Page ...
Страница 8: ...Safety Precautions Notes Before it Works Serving Points to Note at Cleaning ...
Страница 10: ...1 1 Product Outline Product Outline Features Specifications Names of Parts Optional Construction ...
Страница 58: ...3 3 Periodic Servicing Periodic Servicing List of Work for Scheduled Servicing ...
Страница 99: ...5 5 Adjustment Adjustment Outline Basic Adjustment Adjustment at Time of Parts Replacement ...
Страница 133: ...Appendix Service Tools General Circuit Diagram ...