Version 1
imageRUNNER ADVANCE C9075S PRO Customer Expectations Document
Page 25
Main Unit Table Continued
Item
Specifications
Margin
Leading Edge:
4.0 mm +1.5/-1.0 mm
Left and Right:
2.5 mm ±1.5 mm
Warm-Up Time
After Powering ON:
Fewer than 6 minutes
Returning from the Sleep mode:
Fewer than 6 minutes
Returning from the Energy Saver Mode: Fewer than 90 seconds
Activation time may vary, depending on the environment and conditions under
which the machine is being used.
First Print Output Time
Approximately 8 seconds
First Copy Output Time
Approximately 15 seconds (From the platen glass)
Maximum Imageable
Area
12.3” x 18.4” (313 mm x 466.6 mm)
Maximum Printable
Area
12.7” x 18.8” (323 mm x 476.6 mm)
Front-to-Back
Registration Tolerance
Leading Edge:
Up to ±1.5 mm
Left and Right:
Up to ±2.0 mm
Copy/Print Speed
(20 lb bond (80 g/m
2
))
(Except When paper Is
Fed from the
Multi-Purpose Tray)
Paper Size
Black-and-White
Color
13” x 19”
34 ppm
31 ppm
12” x 18”
35 ppm
33 ppm
11” x 17”
38 ppm
35 ppm
LGL
45 ppm
42 ppm
LTR
75 ppm
70 ppm
LTRR
56 ppm
53 ppm
Paper Feeding System/
Capacity
Paper Drawers 1 and 2:
1,100 sheets x 2 drawers (20 lb bond (80 g/m
2
))
Paper Drawers 3 and 4:
550 sheets x 2 cassettes (20 lb bond (80 g/m
2
))
Multi-Purpose Tray:
100 sheets (20 lb bond (80 g/m
2
))
Multiple Prints
1 to 9,999 sheets
Operating Noise
Printing: Approximately 75 dB
Standby: Approximately 58 dB
Ozone Emissions
0.01 ppm (parts per million) or less (Initial Startup)
0.035 ppm or less (After a short break-in period)
Power Source
208 V AC, 60 HZ, 15 A
Maximum Power
Consumption
Main Unit:
Maximum:
Approximately 2.0 kW or less
In Sleep Mode: Approximately 1.5 W or less
TEC (Typical Electricity
Consumption)
17.48 kWh (Including the main unit, duplex color image reader, and copy tray)
Dimensions (H x W x D)
(With the Duplex Color
Image Reader Unit-A1
and Operator Panel)
55.1” (65.0”
*1
) x 44.1” (50.2”
*2
) x 36.7”
(1,400 mm (1,650 mm
*1
) x 1,120 mm (1,275 mm
*2
) x 932 mm)
*1 To the top of the attention light.