2-3) Remove the 4 screws [1], and remove the saddle unit auxiliary caster [2].
2-4) Remove the 6 screws [1], and remove the cover [2] on the lower side of the saddle unit.
2-5) Remove the 4 connectors [1], 3 wire saddles [2], 3 wire clamps [3] and 1 edge saddle [4].
2-6) Remove the 5 screws [1], remove the saddle stopper assembly [2] in the arrow direction, and replace the saddle stopper
assembly with the saddle stopper assembly (FM1-R635-000) which was newly set up as a service part.
[Attention] When pulling out the assembly, don't catch the harness.
17
Содержание imageRUNNER ADVANCE 6500 series
Страница 1: ...Troubleshooting Guide imageRUNNER ADVANCE 8500 6500 Series April 2018 OIP Field Quality Assurance Div ...
Страница 37: ...iR ADV 8585i 120V USA G SWP00501 iR ADV 8505 220V CN SWE00105 33 ...
Страница 53: ...4 5 Make some prints and check that the above issue does not occur 49 ...
Страница 66: ...2 Remove the grate shaped lower guide 2 screws 2 62 ...
Страница 70: ...7 Reattach the metal plate 1 Screw 2 x1 8 Loosen the 2 screws 1 66 ...
Страница 74: ...iR ADV 8505 220V CN To be informed as soon as identified 70 ...
Страница 90: ... Service parts FM4 0889 010 solenoid assembly 86 ...