Chapter 17
17-25
T-17-31
17.5 FUNCTION (Operation/Inspection Mode)
17.5.1 COPIER
17.5.1.1 COPIER List
0015-5971
iR5065 / iR 5055 / iR5075 / / /
<INSTALL>
T-17-32
<CCD>
T-17-33
COPIER > SORTER > ADJUST
Sub-item
Description
Level
PNCH-HLE
Use it to adjust the length from the edge of paper to the punch hole.
settings range: -4 to 2 (unit: mm)
1
COPIER > FUNCTION > INSTALL
Sub-item
Description
Level
TONER-S
Use it to stir the toner inside the developing assembly at time of installation.
Procedure
1. Select the item to highlight.
2. See that the message "Check the developer" is indicated.
At this time, check to see that the developing assembly is correctly mounted.
3. Press the OK key to start the operation. The operation will automatically stop after a specific period of time.
during operation, time remaining (sec): at the end, if successful, '0'; if error, '0xFFFF'.
1
CARD
Use it to set up the card reader.
Procedure
Enter the number of a specific card (0 to 2001), and press the OK key. (As many as 100 cards may be used, starting from the number
you have entered.)
At this time, initialization will take place for card control information (group ID and ID No.).
1
E-RDS
Use it to specify the use of E-RDS.
0: off (do not use; default)
1: use RDS (transmit all counter information)
1
RGW-PORT
Use it to set the Sales Company server port number used for embedded-RDS.
settings range: 1 to 6535
1
COM-TEST
Use it to check the connection to the server used for E-RDS.
Procedure
1) Select the item to highlight, and press the OK key.
2) See where a connection has been made. (The result will be indicated as 'OK' or 'NG'.)
OK: connection possible; NG: connection not possible
1
COM-LOG
Use it to indicate the details of the result of the communication test executed for the server used for E-RDS.
Procedure
1) Select the item to highlight, and press [show info].
log information particulars: year, date, time, error code, error detail (128 characters max.)
1
RGW-ADR
Use it to specify the URL of the server used for E-RDS.
Procedure
1) Select the item to highlight, and press [show information].
2) When the URL input screen appears, enter the appropriate URL and press the OK key.
(default: https://a01.ugwdevice.net/ugw/agnetif010)
1
STRD-POS
Use it to adjust the face (CCD) read position for DADF stream reading mode.
settings range: 1 to 200 [default: 100] (unit: 0.1 mm)
1
CNT-DATE
Setting of the start date to send counter information to the server.
Set the start date to send counter information to the server by the third party advanced function for Embedded-RDS (eRDS).
[Remarks] This mode is displayed only when the third party advanced function for eRDS is available.
Setting range: YYYY: year, MM: month, HH: hour, MM: minute
Factory setting value: 000000000000 (12 digits: YYYYMMDDHHMM)
1
CNT-INTV
Setting of the interval to send counter information to the server.
Set the interval to send counter information to the server by the third party advanced function for Embedded-RDS (eRDS).
[Remarks] This mode is displayed only when the third party advanced function for eRDS is available.
Setting range: 1 to 168 (for a week)
Factory setting value: 24
1
COPIER > FUNCTION > CCD
Sub-item
Description
Level
CCD-ADJ
Use it to execute CCD auto adjustment.
Procedure
1) Place about 10 sheets of paper (the whitest of all papers used by the user, other than color print paper) on the platen glass.
2) Select <CCD-ADJ> to highlight, and press the OK key.
3) See that auto adjustment takes place (about 15 sec). During adjustment, <ACTIVE> will be indicated.
4) See that the scanning lamp goes on twice during adjustment. At the end, the screen will show <OK!>.
5) See that al items of service mode have been updated (COPIER>ADJUST>CCD). Record the new settings on the service label.
If you have replaced the CCD unit, scanning lamp, inverter PCB, or platen board glass (standard white plate), be sure to execute
this mode item.
1
Содержание imageRUNNER 5065 series
Страница 1: ...Feb 26 2007 Service Manual iR5075 5065 5055 Series ...
Страница 2: ......
Страница 6: ......
Страница 27: ...Chapter 1 Introduction ...
Страница 28: ......
Страница 30: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 98: ...Chapter 2 2 42 ...
Страница 99: ...Chapter 3 Basic Operation ...
Страница 100: ......
Страница 102: ......
Страница 108: ......
Страница 109: ...Chapter 4 Main Controller ...
Страница 110: ......
Страница 112: ......
Страница 129: ...Chapter 5 Original Exposure System ...
Страница 130: ......
Страница 162: ......
Страница 163: ...Chapter 6 Laser Exposure ...
Страница 164: ......
Страница 166: ......
Страница 172: ......
Страница 173: ...Chapter 7 Image Formation ...
Страница 174: ......
Страница 178: ......
Страница 210: ......
Страница 211: ...Chapter 8 Pickup Feeding System ...
Страница 212: ......
Страница 263: ...Chapter 9 Fixing System ...
Страница 264: ......
Страница 268: ......
Страница 307: ...Chapter 10 External and Controls ...
Страница 308: ......
Страница 312: ......
Страница 321: ...Chapter 10 10 9 F 10 8 ...
Страница 345: ...Chapter 11 MEAP ...
Страница 346: ......
Страница 348: ......
Страница 389: ...Chapter 12 RDS ...
Страница 390: ......
Страница 392: ......
Страница 399: ...Chapter 13 Maintenance and Inspection ...
Страница 400: ......
Страница 402: ......
Страница 411: ...Chapter 14 Standards and Adjustments ...
Страница 412: ......
Страница 440: ......
Страница 441: ...Chapter 15 Correcting Faulty Images ...
Страница 442: ......
Страница 444: ......
Страница 470: ......
Страница 471: ...Chapter 16 Self Diagnosis ...
Страница 472: ......
Страница 474: ......
Страница 493: ...Chapter 17 Service Mode ...
Страница 494: ......
Страница 496: ......
Страница 552: ......
Страница 553: ...Chapter 18 Upgrading ...
Страница 554: ......
Страница 556: ......
Страница 572: ...Chapter 18 18 16 F 18 29 2 Click Start F 18 30 3 When the session has ended click OK ...
Страница 587: ...Chapter 18 18 31 F 18 59 2 Select the data to download F 18 60 3 Click Start ...
Страница 589: ...Chapter 19 Service Tools ...
Страница 590: ......
Страница 591: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 List of Special Tools 19 1 19 1 2 List of Solvents Oils 19 1 ...
Страница 592: ......
Страница 595: ...Feb 26 2007 ...
Страница 596: ......