9
9
9-72
9-72
Installation > Cassette Heater Unit 37 > Installation Procedure > In case of Host Machine(250 Sheets of Cassette Model)
Installation > Cassette Heater Unit 37 > Installation Procedure > In case of Host Machine(250 Sheets of Cassette Model)
17) Connect the connector at the heater side to the Heater Relay Harness.
F-9-163
18) Affix the Warning High Temperature Label to the specified area. (area between screw holes on the Base Plate)
CAUTION:
Label Warning high
temp label use a label
corresponding to the
language.
Warning high temp label
F-9-164
19) Install the
Heater PCB.
20) Connect
4 connectors to
the
Heater PCB.
21) I
nstall the removed covers.
Lower rear cover
Connector cover
Delivery tray
Inside base cover
Screw on Left cover
Right cover(upper)
22) Close the Right cover.
23) Close the Toner supply cover.
24) Close the Front cover.
25) Install the removed Cassettes.
26) Check that the Environment Heater switch is ON
27) Plug the power plug of the host machine to the outlet.
28) Turn ON the main power switch.
•
•
•
•
•
•
Содержание imageRUNNER 2520
Страница 1: ...9 8 7 6 5 4 3 2 1 imageRUNNER 2530 2525 2520 Series Service Manual ...
Страница 4: ...Blank Page ...
Страница 16: ...1 1 Product Overview Product Overview Product Lineup Feature Specifications Name of Parts ...
Страница 111: ...3 3 Periodical Service Periodical Service Consumable Parts and Cleaning Parts ...
Страница 159: ...5 5 Adjustment Adjustment Outline Adjustment when replacing parts Image position adjustment ...
Страница 166: ...6 6 Troubleshooting Troubleshooting Upgrading Targets and Procedure ...
Страница 171: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 186: ...8 8 Service Mode Service Mode Outline Details of Service Mode ...
Страница 321: ...Service Tools General Circuit Diagram Appendix ...