4
4
4-32
4-32
Parts Replacement and Cleaning > Main Units/Parts > Removing the ADF Scan Glass
Parts Replacement and Cleaning > Main Units/Parts > Removing the ADF Scan Glass
Removing the Platen Glass
1) Open the platen cover (platen board cover/ADF).
2) Remove the glass retainer.(
"Removing the Platen Glass"(page 4-19).
)
2 screws
x2
CAUTION:
When removing the platen glass, take care not to touch the following
parts with your fingers:
Glass surface
Standard white plate
•
•
Soils on these parts may cause white/black lines on images.
If they are soiled, clean them with a lint-free paper moistened with alcohol.
•
F-4-64
F-4-64
F-4-65
F-4-65
Action to Take after Replacing the Platen Glass
Take the action stated below in the service mode.
CAUTION:
Be sure to make the white plate data adjustment before ADF white level adjustment.
W-PLT-X
W-PLT-Y
W-PLT-Z
F-4-66
F-4-66
1.Enter the value indicated on the platen glass in the following service mode:
SCAN > READER > ADJUST > CCD > W-PLT-X/Y/Z (Input of standard white plate data)
2.Enter the service mode, and then select the following:
SCAN > READER > FUNCTION > CCD > DF-WLVL1/2/3/4 (DF white level adjustment)
1)
Place a sheet of paper that the user usually uses on the platen glass, enter the
service mode, and then select SCAN > READER > FUNCTION > CCD > DFWLVL1.
Read the white level in the BOOK mode. (Check the transparency of the glass for
BOOK mode.)
2)
Place a sheet of paper that the user usually uses on the DF, enter the service mode,
and then select SCAN > READER > FUNCTION > CCD > DF-WLVL2.
Read the white level in the DF mode (stream reading). (Check the transparency of
the glass for stream reading.)(Read both sides of the chart.)
3)
Place a sheet of paper that the user usually uses on the platen glass, enter the
service mode, and then select SCAN > READER > FUNCTION > CCD > DFWLVL3.
Read the white level in the BOOK mode. (Check the transparency of the glass for
BOOK mode.)
4)
Place a sheet of paper that the user usually uses on the DF, enter the service mode,
and then select SCAN > READER > FUNCTION > CCD > DF-WLVL4.
Read the white level in the DF mode (stream reading). (Check the transparency of
the glass for stream reading.)(Read both sides of the chart.)
■
Содержание imageRUNNER 2520
Страница 1: ...9 8 7 6 5 4 3 2 1 imageRUNNER 2530 2525 2520 Series Service Manual ...
Страница 4: ...Blank Page ...
Страница 16: ...1 1 Product Overview Product Overview Product Lineup Feature Specifications Name of Parts ...
Страница 111: ...3 3 Periodical Service Periodical Service Consumable Parts and Cleaning Parts ...
Страница 159: ...5 5 Adjustment Adjustment Outline Adjustment when replacing parts Image position adjustment ...
Страница 166: ...6 6 Troubleshooting Troubleshooting Upgrading Targets and Procedure ...
Страница 171: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...